Quantitative imaging biomarkers alliance (QIBA) recommendations for improved precision of DWI and DCE‐MRI derived biomarkers in multicenter oncology trials

A Shukla‐Dave, NA Obuchowski… - Journal of Magnetic …, 2019 - Wiley Online Library
Physiological properties of tumors can be measured both in vivo and noninvasively by
diffusion‐weighted imaging and dynamic contrast‐enhanced magnetic resonance imaging …

What are normal relaxation times of tissues at 3 T?

JZ Bojorquez, S Bricq, C Acquitter, F Brunotte… - Magnetic resonance …, 2017 - Elsevier
The T 1 and T 2 relaxation times are the basic parameters behind magnetic resonance
imaging. The accurate knowledge of the T 1 and T 2 values of tissues allows to perform …

Magnetic resonance fingerprinting

D Ma, V Gulani, N Seiberlich, K Liu, JL Sunshine… - Nature, 2013 - nature.com
Magnetic resonance is an exceptionally powerful and versatile measurement technique. The
basic structure of a magnetic resonance experiment has remained largely unchanged for …

Multiparametric imaging with heterogeneous radiofrequency fields

MA Cloos, F Knoll, T Zhao, KT Block, M Bruno… - Nature …, 2016 - nature.com
Magnetic resonance imaging (MRI) has become an unrivalled medical diagnostic technique
able to map tissue anatomy and physiology non-invasively. MRI measurements are …

Variability and standardization of quantitative imaging: monoparametric to multiparametric quantification, radiomics, and artificial intelligence

A Hagiwara, S Fujita, Y Ohno, S Aoki - Investigative radiology, 2020 - journals.lww.com
Radiological images have been assessed qualitatively in most clinical settings by the expert
eyes of radiologists and other clinicians. On the other hand, quantification of radiological …

MR fingerprinting of adult brain tumors: initial experience

C Badve, A Yu, S Dastmalchian… - American Journal …, 2017 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: MR fingerprinting allows rapid simultaneous quantification
of T1 and T2 relaxation times. This study assessed the utility of MR fingerprinting in …

Fast 3D magnetic resonance fingerprinting for a whole‐brain coverage

D Ma, Y Jiang, Y Chen, D McGivney… - Magnetic resonance …, 2018 - Wiley Online Library
Purpose The purpose of this study was to accelerate the acquisition and reconstruction time
of 3D magnetic resonance fingerprinting scans. Methods A 3D magnetic resonance …

Improved magnetic resonance fingerprinting reconstruction with low‐rank and subspace modeling

B Zhao, K Setsompop, E Adalsteinsson… - Magnetic resonance …, 2018 - Wiley Online Library
Purpose This article introduces a constrained imaging method based on low‐rank and
subspace modeling to improve the accuracy and speed of MR fingerprinting (MRF). Theory …

Slice profile and B1 corrections in 2D magnetic resonance fingerprinting

D Ma, S Coppo, Y Chen, DF McGivney… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose The goal of this study is to characterize and improve the accuracy of 2D magnetic
resonance fingerprinting (MRF) scans in the presence of slice profile (SP) and B1 …

Repeatability of magnetic resonance fingerprinting T1 and T2 estimates assessed using the ISMRM/NIST MRI system phantom

Y Jiang, D Ma, KE Keenan, KF Stupic… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose The purpose of this study was to evaluate accuracy and repeatability of T1 and T2
estimates of a MR fingerprinting (MRF) method using the ISMRM/NIST MRI system phantom …