A review of recent advances in tribology
Y Meng, J Xu, Z Jin, B Prakash, Y Hu - Friction, 2020 - Springer
The reach of tribology has expanded in diverse fields and tribology related research
activities have seen immense growth during the last decade. This review takes stock of the …
activities have seen immense growth during the last decade. This review takes stock of the …
FEM wear prediction of ceramic hip replacement bearings under dynamic edge loading conditions
KN Prasad, P Ramkumar - Journal of the Mechanical Behavior of …, 2023 - Elsevier
Hard-on-Hard hip implants, specifically ceramic tribo-pair, have produced the highest in-vivo
wear resistance, biocompatibility, superior corrosion resistance, and high fracture …
wear resistance, biocompatibility, superior corrosion resistance, and high fracture …
Low pressure plasma nitrided CoCrMo alloy utilising HIPIMS discharge for biomedical applications
K Shukla, AA Sugumaran, I Khan, AP Ehiasarian… - Journal of The …, 2020 - Elsevier
CoCrMo is a biomedical grade alloy which is widely used in the manufacturing of
orthopaedic implants such as hip and knee replacement joints because of it has high …
orthopaedic implants such as hip and knee replacement joints because of it has high …
Dry sliding wear mechanisms of HIPIMS plasma nitrided CoCrMo alloy for medical implant applications
AA Sugumaran, K Shukla, I Khan, AP Ehiasarian… - Vacuum, 2021 - Elsevier
Unlike the state-of-the-art plasma nitriding technologies where a low ionisation glow
discharge is used, nitriding of CoCrMo alloy was carried out in an industrial size vacuum …
discharge is used, nitriding of CoCrMo alloy was carried out in an industrial size vacuum …
Less early subsidence of cemented Exeter short stems compared with cemented Exeter standard stems in Dorr type A femurs: a radiostereometry study with minimum …
PB Jørgensen, SS Jakobsen, D Vainorius… - Bone & Joint …, 2023 - boneandjoint.org.uk
Aims The Exeter short stem was designed for patients with Dorr type A femora and short-
term results are promising. The aim of this study was to evaluate the minimum five-year stem …
term results are promising. The aim of this study was to evaluate the minimum five-year stem …
[HTML][HTML] Estimation of two wear factors for total hip arthroplasty: A simulation study based on musculoskeletal modelling
Background Primary causes of surgical revision after total hip arthroplasty are polyethylene
wear and implant loosening. These factors are particularly related to joint friction and thus …
wear and implant loosening. These factors are particularly related to joint friction and thus …
A case-driven hypothesis for multi-stage crack growth mechanism in fourth-generation ceramic head fracture
S Lucchini, M Baleani, F Giardina, A Martelli… - Journal of Orthopaedic …, 2022 - Springer
Background Ceramic bearings are used in total hip arthroplasty due to their excellent wear
behaviour and biocompatibility. The major concern related to their use is material brittleness …
behaviour and biocompatibility. The major concern related to their use is material brittleness …
The concentration of chromium and cobalt ions and parameters of oxidative stress in serum and their impact on clinical outcomes after metaphyseal hip arthroplasty …
T Stołtny, M Dobrakowski, A Augustyn… - Journal of Orthopaedic …, 2023 - Springer
Purpose Current epidemiological data forecast an almost 40% increase in the number of hip
arthroplasty performed in the population of patients with osteoarthritis in 2060, compared to …
arthroplasty performed in the population of patients with osteoarthritis in 2060, compared to …
[HTML][HTML] The occurrence of squeaking under wear testing standards for ceramic on ceramic total hip replacements
OOD Lancaster-Jones, R Reddiough - Journal of the Mechanical Behavior …, 2023 - Elsevier
Ceramic on ceramic total hip replacement clinical reports may on occasion note a noise or
squeaking. There is much debate on whether this is an actual concern, but some medical …
squeaking. There is much debate on whether this is an actual concern, but some medical …
A computational parametric study on edge loading in ceramic-on-ceramic total hip joint replacements
F Liu, L Feng, J Wang - Journal of the mechanical behavior of biomedical …, 2018 - Elsevier
Edge loading in ceramic-on-ceramic total hip joint replacement is an adverse condition that
occurs as the result of a direct contact between the head and the cup rim. It has been …
occurs as the result of a direct contact between the head and the cup rim. It has been …