Monte Carlo modelling of external radiotherapy photon beams
F Verhaegen, J Seuntjens - Physics in medicine & biology, 2003 - iopscience.iop.org
An essential requirement for successful radiation therapy is that the discrepancies between
dose distributions calculated at the treatment planning stage and those delivered to the …
dose distributions calculated at the treatment planning stage and those delivered to the …
[PDF][PDF] BEAMnrc users manual
DWO Rogers, B Walters, I Kawrakow - Nrc Report Pirs, 2009 - nrc-cnrc.github.io
Abstract BEAMnrc is a Monte Carlo simulation system (Med. Phys. 22, 1995, 503–524) for
modelling radiotherapy sources which was developed as part of the OMEGA project to …
modelling radiotherapy sources which was developed as part of the OMEGA project to …
DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations
J Sempau, SJ Wilderman… - Physics in Medicine & …, 2000 - iopscience.iop.org
Abstract A new Monte Carlo (MC) algorithm, thedose planning method'(DPM), and its
associated computer program for simulating the transport of electrons and photons in …
associated computer program for simulating the transport of electrons and photons in …
Summary and recommendations of a National Cancer Institute workshop on issues limiting the clinical use of Monte Carlo dose calculation algorithms for megavoltage …
BA Fraass, J Smathers, J Deye - Medical physics, 2003 - Wiley Online Library
Due to the significant interest in Monte Carlo dose calculations for external beam
megavoltage radiation therapy from both the research and commercial communities, a …
megavoltage radiation therapy from both the research and commercial communities, a …
Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC
I Kawrakow, M Fippel - Physics in Medicine & Biology, 2000 - iopscience.iop.org
Several variance reduction techniques, such as photon splitting, electron history repetition,
Russian roulette and the use of quasi-random numbers are investigated and shown to …
Russian roulette and the use of quasi-random numbers are investigated and shown to …
Monte Carlo simulation of electron beams from an accelerator head using PENELOPE
J Sempau, A Sánchez-Reyes, F Salvat… - Physics in Medicine …, 2001 - iopscience.iop.org
Abstract The Monte Carlo code PENELOPE has been used to simulate electron beams from
a Siemens Mevatron KDS linac with nominal energies of 6, 12 and 18 MeV. Owing to its …
a Siemens Mevatron KDS linac with nominal energies of 6, 12 and 18 MeV. Owing to its …
Clinical implementation of a Monte Carlo treatment planning system
CM Ma, E Mok, A Kapur, T Pawlicki, D Findley… - Medical …, 1999 - Wiley Online Library
The purpose of this study was to implement the Monte Carlo method for clinical radiotherapy
dose calculations. We used the EGS4/BEAM code to obtain the phase‐space data for 6–20 …
dose calculations. We used the EGS4/BEAM code to obtain the phase‐space data for 6–20 …
Validation of GEANT4, an object‐oriented Monte Carlo toolkit, for simulations in medical physics
geant4 (GEometry ANd Tracking 4) is an object‐oriented Monte Carlo simulation toolkit that
has been developed by a worldwide collaboration of scientists. It simulates the passage of …
has been developed by a worldwide collaboration of scientists. It simulates the passage of …
Inverse planning for intensity-modulated arc therapy using direct aperture optimization
MA Earl, DM Shepard, S Naqvi, XA Li… - Physics in Medicine & …, 2003 - iopscience.iop.org
Intensity-modulated arc therapy (IMAT) is a radiation therapy delivery technique that
combines gantry rotation with dynamic multi-leaf collimation (MLC). With IMAT, the benefits …
combines gantry rotation with dynamic multi-leaf collimation (MLC). With IMAT, the benefits …
Photon beam characterization and modelling for Monte Carlo treatment planning
Abstract Photon beams of 4, 6 and 15 MV from Varian Clinac 2100C and 2300C/D
accelerators were simulated using the EGS4/BEAM code system. The accelerators were …
accelerators were simulated using the EGS4/BEAM code system. The accelerators were …