Frequency characteristics of leakage current waveforms of a string of suspension insulators
T Suda - IEEE Transactions on power delivery, 2005 - ieeexplore.ieee.org
In order to establish a method for monitoring whether flashover occurs or not in a string of
insulators based on leakage current waveforms and their frequency characteristics, the …
insulators based on leakage current waveforms and their frequency characteristics, the …
Fundamental and low frequency harmonic components of leakage current as a diagnostic tool to study aging of RTV and HTV silicone rubber in salt-fog
AH El-Hag, SH Jayaram… - IEEE Transactions on …, 2003 - ieeexplore.ieee.org
The paper presents the results of using the fundamental and the low frequency harmonic
components of leakage current to study aging of silicone rubber in salt-fog. Experiments …
components of leakage current to study aging of silicone rubber in salt-fog. Experiments …
Ageing of silicone rubber insulators in coastal and inland tropical environment
M Fernando, SM Gubanski - IEEE Transactions on Dielectrics …, 2010 - ieeexplore.ieee.org
This paper presents investigations on the performance of 33 kV silicone rubber insulators
characterized by different creepage lengths, which aimed to find out whether the insulators …
characterized by different creepage lengths, which aimed to find out whether the insulators …
Challenges and issues of using polymers as structural materials in MEMS: A review
Y Li - Journal of Microelectromechanical Systems, 2018 - ieeexplore.ieee.org
Polymers are ever more widely and more prominently used in microelectromechanical
systems. They provide significant added value to the existing silicon-based technologies …
systems. They provide significant added value to the existing silicon-based technologies …
Aging evaluation of silicone rubber insulators using leakage current and flashover voltage analysis
I Ahmadi-Joneidi, A Majzoobi… - … on Dielectrics and …, 2013 - ieeexplore.ieee.org
Ultraviolet (UV) radiation decreases the hydrophobicity of silicone rubber (SiR) insulators.
Lack of hydrophobicity on the surface of such insulators lowers the flashover voltage and …
Lack of hydrophobicity on the surface of such insulators lowers the flashover voltage and …
Leakage current characterization for estimating the conditions of ceramic and polymeric insulating surfaces
S Kumagai, N Yoshimura - IEEE Transactions on Dielectrics …, 2004 - ieeexplore.ieee.org
Leakage current produced on contaminated ceramic and polymeric insulating surfaces was
analyzed using a wavelet transform technique providing time-frequency domain information …
analyzed using a wavelet transform technique providing time-frequency domain information …
Determining the probability of flashover occurrence in composite insulators by using leakage current harmonic components
HH Kordkheili, H Abravesh, M Tabasi… - … on Dielectrics and …, 2010 - ieeexplore.ieee.org
Flashover of contaminated insulators in polluted areas is one of the most important factors
influencing the operation of transmission and distribution lines and substations. Hence …
influencing the operation of transmission and distribution lines and substations. Hence …
Contamination level prediction of insulators based on the characteristics of leakage current
J Li, C Sun, W Sima, Q Yang… - IEEE transactions on power …, 2009 - ieeexplore.ieee.org
In order to assess how severe the contamination level of the surface of power line insulators
and to prevent unpredictable contamination flashovers, it is important to seek optimal …
and to prevent unpredictable contamination flashovers, it is important to seek optimal …
Performance of outdoor insulators in tropical conditions of Sri Lanka
S Kumara, M Fernando - IEEE Electrical Insulation Magazine, 2020 - ieeexplore.ieee.org
Ceramic insulators, specifically porcelain and glass insulators, have widely been used all
over the world since the 19th century [1, 2]. However, when such insulators are energized …
over the world since the 19th century [1, 2]. However, when such insulators are energized …
Odd harmonics and third to fifth harmonic ratios of leakage currents as diagnostic tools to study the ageing of glass insulators
This paper reports an investigation into the leakage current harmonic components of 45
units of glass insulator samples. The insulator units comprise 5 groups of insulators: new …
units of glass insulator samples. The insulator units comprise 5 groups of insulators: new …