Condition-based maintenance methods for marine renewable energy
A Mérigaud, JV Ringwood - Renewable and Sustainable Energy Reviews, 2016 - Elsevier
With an increasing requirement to lower the costs of delivered renewable energy, the
maintenance costs for marine renewable energy (MRE), due to accessibility issues, are an …
maintenance costs for marine renewable energy (MRE), due to accessibility issues, are an …
Protection techniques with renewable resources and smart grids—A survey
MM Eissa - Renewable and sustainable energy reviews, 2015 - Elsevier
Interconnection between countries and surrounding countries provides a large power grid.
With the improvement of wind power technology, increase of wind power capacity, the …
With the improvement of wind power technology, increase of wind power capacity, the …
[HTML][HTML] Measuring impedance frequency characteristics of magnetic rings with DC-bias current
K Kutorasiński, M Szewczyk, M Molas, J Pawłowski - ISA transactions, 2023 - Elsevier
This paper reports on a comprehensive study on a measurement method for the impedance
characteristics in the frequency domain of magnetic rings as a function of DC-bias current up …
characteristics in the frequency domain of magnetic rings as a function of DC-bias current up …
Development of improved suppression measures against reignition overvoltages caused by vacuum circuit breakers in offshore wind farms
Y Xin, B Zhao, Q Liang, J Zhou, T Qian… - … on Power Delivery, 2021 - ieeexplore.ieee.org
In offshore wind farms, reignition overvoltages are usually caused by switching-off
operations of vacuum circuit breakers, which degrade the insulation of power equipment …
operations of vacuum circuit breakers, which degrade the insulation of power equipment …
Configuration of suppression schemes against high-frequency transient reignition overvoltages caused by shunt reactor switching-off in offshore wind farms
YL Xin, YH Yang, BN Zhao, L Xu, ZY Yu… - International Journal of …, 2022 - Elsevier
It is crucial to protect offshore wind farms from overvoltages because of bad accessibility and
high maintenance costs. During the process of switching-off a shunt reactor with a 40.5 kV …
high maintenance costs. During the process of switching-off a shunt reactor with a 40.5 kV …
Development of an adaptive differential protection scheme for transformer during current transformer saturation and over‐fluxing condition
Despite having several modern transformer protection schemes, the protection engineer
prefers the universally adopted unit‐type differential protection scheme for the current …
prefers the universally adopted unit‐type differential protection scheme for the current …
Investigation on overvoltage caused by vacuum circuit breaker switching off shunt reactor in offshore wind farms
The multiple reignitions of vacuum circuit braker (VCB) while switching off the shunt reactor
in an offshore wind farm (OWF) would produce a high overvoltage. The post‐arc process of …
in an offshore wind farm (OWF) would produce a high overvoltage. The post‐arc process of …
Simulation and protection of reignition overvoltage in wind farm considering microscopic dielectric recovery process of vacuum circuit breaker
Z Pu, H Liu, Y Wang, X Yu, T Wu - Energies, 2023 - mdpi.com
The high amplitude and steep overvoltage generated by the breaking of the vacuum circuit
breaker in the wind farm damages the inter-turn insulation of the transformer. There is a …
breaker in the wind farm damages the inter-turn insulation of the transformer. There is a …
Nonlinear modeling of magnetic materials for circuit simulations
K Kutorasiński, J Pawłowski, P Leszczyński… - Scientific Reports, 2023 - nature.com
Magnetic materials in the form of magnetic rings are widely used in power engineering
products. In many cases, they operate in high frequency and in nonlinear conditions, eg, as …
products. In many cases, they operate in high frequency and in nonlinear conditions, eg, as …
Multifrequency nonlinear model of magnetic material with artificial intelligence optimization
Magnetic rings are extensively used in power products where they often operate in high
frequency and high current conditions, such as for mitigation of excessive voltages in high …
frequency and high current conditions, such as for mitigation of excessive voltages in high …