Innovative load shedding scheme to restore synchronous generator-based microgrids during FIDVR
R Bekhradian, M Sanaye-Pasand… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Fault induced voltage recovery (FIDVR) phenomenon may occur in microgrids (Gs) and
distribution systems due to the induction motors (IMs) behavior after system voltage sags …
distribution systems due to the induction motors (IMs) behavior after system voltage sags …
Load shedding method aimed fast voltage recovery to prevent interference of FIDVR with UV relays
M Ghotbi‐Maleki, R Mohammadi… - IET Generation …, 2023 - Wiley Online Library
The fault‐induced delayed voltage recovery (FIDVR) and short‐term voltage instability
(STVI) phenomena appear in networks with high penetration of induction motor loads …
(STVI) phenomena appear in networks with high penetration of induction motor loads …
Novel relative slip based under-voltage load shedding protection scheme to mitigate FIDVR
AH Mohammadi, M Abedini… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Induction motors play a vital role in the voltage stability of power systems. This role would
become more significant after clearing short-circuit faults in which the system voltage slowly …
become more significant after clearing short-circuit faults in which the system voltage slowly …
Classification of electrical power system conditions with convolutional neural networks
M Kiruthika, S Bindu - Engineering, Technology & Applied Science …, 2020 - etasr.com
Undesirable operation of a distant relay at the occurrence of stressed conditions is a reason
for blackouts. There are a few computational intelligent methods available in the literature for …
for blackouts. There are a few computational intelligent methods available in the literature for …
Shunt capacitor bank: Transient issues and analytical solutions
Medium voltage shunt capacitor banks (SCBs) are widely used for improving voltage profile
and providing reactive power in electrical networks. Transient oscillations caused by SCBs …
and providing reactive power in electrical networks. Transient oscillations caused by SCBs …
FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration
Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays
and batteries into an ac grid. Further, they must be able to restore single-phase induction …
and batteries into an ac grid. Further, they must be able to restore single-phase induction …
A novel framework for operation of capacitor banks in non/semi/fully-automated distribution networks
H Daryabar, M Abedini… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
Nowadays, distribution systems have different levels of automation due to the need for
massive investment. The optimal operation of capacitor banks (CBs) is a widely-used …
massive investment. The optimal operation of capacitor banks (CBs) is a widely-used …
Multi-objective dynamic VAR planning against fault-induced delayed voltage recovery using heuristic optimization
M Bahramgiri, M Ehsan, S Babak Mozafari - Electrical Engineering, 2024 - Springer
The fault-induced delayed voltage recovery (FIDVR) and short-term voltage instability are
increasing, especially due to the widespread implementation of residential air conditioners …
increasing, especially due to the widespread implementation of residential air conditioners …
A network analysis-based distributed load shedding strategy for voltage collapse prevention
A Tian, X Mou - IEEE Access, 2019 - ieeexplore.ieee.org
This paper proposes a network analysis-based distributed load shedding strategy for
voltage collapse prevention. The two-level framework of the distributed load shedding …
voltage collapse prevention. The two-level framework of the distributed load shedding …
Optimal CVSR allocation to ensure network health in static load shedding–a Bi-level optimization approach
MH Hemmatpour, MHR Koochi - Electric Power Systems Research, 2022 - Elsevier
In this paper, a new methodology is proposed for achieving a general load shedding
scheme to prevent power system cascading line outages with the help of continuously …
scheme to prevent power system cascading line outages with the help of continuously …