Two-phase flow distribution in parallel flow mini/micro-channel heat exchangers for refrigeration and heat pump systems: A comprehensive review
T Xiong, G Liu, S Huang, G Yan, J Yu - Applied Thermal Engineering, 2022 - Elsevier
Heat pump and refrigeration systems consume a large amount of energy annually around
the world. Heat exchanger is an important component of heat pump and refrigeration …
the world. Heat exchanger is an important component of heat pump and refrigeration …
Experimental study of flow distribution behavior on the shell side of spiral tube bundles in LNG spiral-wound heat exchangers
Y Wang, F Wang, W Zheng, Z Tian, Y Jiang… - Thermal Science and …, 2023 - Elsevier
Flow maldistribution could reduce the heat transfer capability of LNG spiral-wound heat
exchangers (SWHEs). However, there remains a lack of clarity on the flow distribution …
exchangers (SWHEs). However, there remains a lack of clarity on the flow distribution …
Modeling the uniformity of manifold with various configurations
JM Hassan, TA Mohamed, WS Mohammed… - Journal of …, 2014 - Wiley Online Library
The flow distribution in manifolds is highly dependent on inlet pressure, configuration, and
total inlet flow to the manifold. The flow from a manifold has many applications and in …
total inlet flow to the manifold. The flow from a manifold has many applications and in …
The problem of hydraulic calculation of pressure distribution pipelines
V Cherniuk, R Hnativ, O Kravchuk, V Orel… - … -European Journal of …, 2021 - papers.ssrn.com
Most production technologies require a uniform flow path of liquid from pressure distribution
pipelines. To achieve this goal, it is proposed to introduce polymer additives into the liquid …
pipelines. To achieve this goal, it is proposed to introduce polymer additives into the liquid …
Quantification of flow distribution and heat capacity potential of a microchannel evaporator
H Li, L Wang, H Jiang, H Liu, Q Gao, L Huang - International Journal of …, 2023 - Elsevier
Maldistribution of fluid among the ports reduces the heat capacity of a microchannel heat
exchanger. It is essential to understand the maldistribution mechanism to optimize the …
exchanger. It is essential to understand the maldistribution mechanism to optimize the …
Experimental research on distribution characteristics of biphasic fluids in the shell side of LNG spiral-wound heat exchangers under sloshing conditions
Flow maldistribution on the shell side of LNG spiral-wound heat exchangers (SWHEs) can
deteriorate their performance, especially in the presence of sloshing motions. Nevertheless …
deteriorate their performance, especially in the presence of sloshing motions. Nevertheless …
Quantification of two-phase refrigerant distribution in brazed plate heat exchangers using infrared thermography
This paper presents a method to quantify two-phase refrigerant flow distribution in brazed
plate heat exchangers (BPHEs) from infrared images. In this method, the two-phase length …
plate heat exchangers (BPHEs) from infrared images. In this method, the two-phase length …
Horizontal distribution of two-phase refrigerant in parallel flat mini-channels
NH Kim, MG Go - Experimental Thermal and Fluid Science, 2018 - Elsevier
A literature survey revealed that no prior investigation has been conducted on the horizontal
distribution of a two-phase refrigerant in mini-channel tubes, which may be of importance for …
distribution of a two-phase refrigerant in mini-channel tubes, which may be of importance for …
Quantification of two-phase flow in a microchannel heat exchanger header based on capacitance measurement
J Song, H Liu, C Yuan, R Wang, J Peng, L Wang… - International Journal of …, 2024 - Elsevier
The two-phase distribution has always been one of the research focuses of microchannel
heat exchangers, because the maldistribution could seriously affect the heat transfer …
heat exchangers, because the maldistribution could seriously affect the heat transfer …
Two-phase refrigerant distribution in an intermediate header of a parallel flow minichannel heat exchanger
HW Byun, NH Kim - International Journal of Refrigeration, 2015 - Elsevier
Refrigerant R-410A distribution in a two pass evaporator with intermediate header was
investigated. The number of tubes was 10 for the first pass and 12 for the second pass. Tests …
investigated. The number of tubes was 10 for the first pass and 12 for the second pass. Tests …