Tonometers—which one should I use?
K Aziz, DS Friedman - Eye, 2018 - nature.com
Although several factors are known to play a role in the development and progression of
glaucoma, intraocular pressure (IOP) remains the only modifiable risk factor. Medical and …
glaucoma, intraocular pressure (IOP) remains the only modifiable risk factor. Medical and …
Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group
M Chen, L Zhang, J Xu, X Chen, Y Gu, Y Ren… - BMC …, 2019 - Springer
Background Measurement of intraocular pressure (IOP) is essential for glaucoma patients.
Many factors such as central corneal thickness (CCT) can affect the accuracy of IOP …
Many factors such as central corneal thickness (CCT) can affect the accuracy of IOP …
Meta-analysis of the concordance of Icare® PRO–based rebound and Goldmann applanation tonometry in glaucoma patients
TH Rödter, S Knippschild, C Baulig… - European Journal …, 2020 - journals.sagepub.com
Background: The Icare® PRO rebound tonometer is being promoted as a patient-friendly
device for glaucoma detection and monitoring, allowing rapid and accurate intraocular …
device for glaucoma detection and monitoring, allowing rapid and accurate intraocular …
The Icare HOME (TA022) study: performance of an intraocular pressure measuring device for self-tonometry by glaucoma patients
Purpose To evaluate the Icare HOME (TA022) device (Icare Oy, Vanda, Finland) for use by
glaucoma patients for self-tonometry. Design Prospective performance evaluation of a …
glaucoma patients for self-tonometry. Design Prospective performance evaluation of a …
Agreement among Goldmann applanation tonometer, iCare, and Icare PRO rebound tonometers; non-contact tonometer; and Tonopen XL in healthy elderly subjects
Y Kato, S Nakakura, N Matsuo, K Yoshitomi… - International …, 2018 - Springer
Purpose To evaluate the inter-device agreement among the Goldmann applanation
tonometer (GAT), iCare and Icare PRO rebound tonometers, non-contact tonometer (NCT) …
tonometer (GAT), iCare and Icare PRO rebound tonometers, non-contact tonometer (NCT) …
Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer
F Gao, X Liu, Q Zhao, Y Pan - Experimental and …, 2017 - spandidos-publications.com
Tonometry is a fundamental procedure in routine ophthalmologic examination. Although
regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its …
regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its …
Agreement of intraocular pressure measurement of Icare ic200 with Goldmann applanation tonometer in adult eyes with normal cornea
SV Badakere, R Chary, NS Choudhari, HL Rao… - Ophthalmology …, 2021 - Elsevier
Purpose To study the agreement between the Icare ic200 (ICare Finland Oy, Helsinki,
Finland) and the Goldmann Applanation Tonometer (GAT) in the measurement of intraocular …
Finland) and the Goldmann Applanation Tonometer (GAT) in the measurement of intraocular …
Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous subjects
SP Bang, CE Lee, YC Kim - BMC ophthalmology, 2017 - Springer
Background To compare the measurement of intraocular pressure (IOP) among the three
different non-contact tonometers (NCT) and the Goldmann applanation tonometer (GAT) for …
different non-contact tonometers (NCT) and the Goldmann applanation tonometer (GAT) for …
Intraocular pressure measurement after corneal transplantation
BPS Bezerra, E Chan, R Chakrabarti… - Survey of …, 2019 - Elsevier
Measurement of intraocular pressure is an integral part of a comprehensive ocular
examination, especially after a surgical intervention that can affect aqueous humor flow …
examination, especially after a surgical intervention that can affect aqueous humor flow …
Comparison of rebound tonometry and non-contact airpuff tonometry to Goldmann applanation tonometry
G Demirci, SK Erdur, C Tanriverdi… - Therapeutic …, 2019 - journals.sagepub.com
Purpose: The aim of this study was to compare the intraocular pressure measurements
obtained from healthy subjects with the rebound tonometry, non-contact airpuff tonometry …
obtained from healthy subjects with the rebound tonometry, non-contact airpuff tonometry …