Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis
C Robba, G Santori, M Czosnyka, F Corradi… - Intensive care …, 2018 - Springer
Purpose Although invasive intracranial devices (IIDs) are the gold standard for intracranial
pressure (ICP) measurement, ultrasonography of the optic nerve sheath diameter (ONSD) …
pressure (ICP) measurement, ultrasonography of the optic nerve sheath diameter (ONSD) …
[HTML][HTML] Monitoring of intracranial pressure in patients with traumatic brain injury
C Hawthorne, I Piper - Frontiers in neurology, 2014 - frontiersin.org
Since Monro published his observations on the nature of the contents of the intracranial
space in 1783, there has been investigation of the unique relationship between the contents …
space in 1783, there has been investigation of the unique relationship between the contents …
Ultrasonography assessments of optic nerve sheath diameter as a noninvasive and dynamic method of detecting changes in intracranial pressure
L Wang, L Chen, Y Chen, L Bao, N Zheng… - JAMA …, 2018 - jamanetwork.com
Importance The crtierion standard method for monitoring intracranial pressure (ICP) can
result in complications and pain. Hence, noninvasive, repeatable methods would be …
result in complications and pain. Hence, noninvasive, repeatable methods would be …
Facts and myths of cerebrospinal fluid pressure for the physiology of the eye
The orbital cerebrospinal fluid pressure (CSFP) represents the true counter-pressure against
the intraocular pressure (IOP) across the lamina cribrosa and is, therefore, one of the two …
the intraocular pressure (IOP) across the lamina cribrosa and is, therefore, one of the two …
[HTML][HTML] Optimal optic nerve sheath diameter threshold for the identification of elevated opening pressure on lumbar puncture in a Chinese population
L Wang, L Feng, Y Yao, Y Wang, Y Chen, J Feng… - PLoS …, 2015 - journals.plos.org
Ultrasonography of the optic nerve sheath diameter (ONSD) is a non-invasive and rapid
method that might be helpful in the identification of increased intracranial pressure (ICP) …
method that might be helpful in the identification of increased intracranial pressure (ICP) …
Sonographic assessment of the optic nerve sheath diameter in the diagnosis of idiopathic intracranial hypertension
P del Saz-Saucedo, O Redondo-González… - Journal of the …, 2016 - Elsevier
Objective: Sonographic assessment of the optic nerve sheath diameter (ONSD) is a useful
technique in detecting raised intracranial pressure (ICP) in neurocritical care patients. Its …
technique in detecting raised intracranial pressure (ICP) in neurocritical care patients. Its …
Optic nerve sheath diameter ultrasound evaluation in intensive care unit: possible role and clinical aspects in neurological critical patients' daily monitoring
M Toscano, G Spadetta, P Pulitano… - BioMed research …, 2017 - Wiley Online Library
Background. The increase of the optic nerve sheath diameter (ONSD) is a reliable,
noninvasive sonographic marker of intracranial hypertension. Aim of the study was to …
noninvasive sonographic marker of intracranial hypertension. Aim of the study was to …
Comparison of two techniques to measure optic nerve sheath diameter in patients at risk for increased intracranial pressure
A Agrawal, R Cheng, J Tang, DY Madhok - Critical care medicine, 2019 - journals.lww.com
Objectives: Intracranial pressure over 20 mm Hg is associated with poor neurologic
prognosis, but measuring intracranial pressure directly requires an invasive procedure …
prognosis, but measuring intracranial pressure directly requires an invasive procedure …
Ultrasonographic optic nerve sheath diameter to detect increased intracranial pressure in adults: a meta-analysis
Background The optimal optic nerve sheath diameter (ONSD) cut-off for identifying
increased intracranial pressure (IICP) remains unclear in adult patients. Purpose To validate …
increased intracranial pressure (IICP) remains unclear in adult patients. Purpose To validate …
[HTML][HTML] Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter
L Wang, Y Yao, L Feng, Y Wang, N Zheng, J Feng… - Scientific reports, 2017 - nature.com
We aimed to quantitatively assess intracranial pressure (ICP) using optic nerve sheath
diameter (ONSD) measurements. We recruited 316 neurology patients in whom …
diameter (ONSD) measurements. We recruited 316 neurology patients in whom …