Simulation and experimental investigation of the effects of subdicing on a single element transducer

P Li, W Shao, Z Li, Z Han, Y Xu, J Shen, Y Cui - Applied Acoustics, 2024 - Elsevier
Abstract Structure design of medical ultrasonic transducers is of prime importance, as it not
only affects the transducer's imaging performance, but also limits its application scene and …

Experimental Investigation of the Effect of Subdicing on an Ultrasound Matrix Transducer

DS dos Santos, F Fool, T Kim… - 2021 IEEE …, 2021 - ieeexplore.ieee.org
Over the past decades, real-time three-dimensional (3D) medical ultrasound has attracted
much attention since it enables clinicians to diagnose more accurately. This calls for …

Study of the sound speed of components in a medical ultrasonic one-dimensional array transducer

W Lee, K Kang - Japanese Journal of Applied Physics, 2021 - iopscience.iop.org
In this work the sound speed of components in a one-dimensional array transducer used to
acquire ultrasonic cross-sectional images for medical diagnosis was studied. The transducer …

A tiled ultrasound matrix transducer for volumetric imaging of the carotid artery

DS Dos Santos, F Fool, M Mozaffarzadeh… - Sensors, 2022 - mdpi.com
High frame rate three-dimensional (3D) ultrasound imaging would offer excellent
possibilities for the accurate assessment of carotid artery diseases. This calls for a matrix …

The role of sub-dicing in the acoustical design of an ultrasound matrix transducer for carotid arteries imaging

M Shabanimotlagh, J Janjic… - 2016 IEEE …, 2016 - ieeexplore.ieee.org
Accurate diagnostics of stenosis and blood flow distribution in carotid arteries requires
transducers capable of producing 3D volume images with high frame rate for real time …

3D high frame rate flow measurement using a prototype matrix transducer for carotid imaging

F Fool, HJ Vos, M Shabanimotlagh… - 2019 IEEE …, 2019 - ieeexplore.ieee.org
To accurately investigate the state of the carotid artery by the local haemodynamics and
motion of the plaque using ultrasound, high-frame rate volumetric imaging is necessary. We …

[PDF][PDF] Ultrasound matrix transducers for high frame rate 3D medical imaging

M Shabanimotlagh - 2018 - pure.tudelft.nl
This thesis describes the design, fabrication, and characterization of a Lead-Zirconate-
Titanate (PZT) matrix transducer integrated on an Application Specific Integrated Circuit …

Design of a Dual Frequency Probe for Photoacoustic Imaging of the Carotid Artery

RP Zangabad, HJ Vos, N De Jong… - 2020 IEEE …, 2020 - ieeexplore.ieee.org
A dual frequency probe using a multi-layer piezoelectric material is proposed for
simultaneous ultrasound and photoacoustic imaging of the carotid artery with a high …