AAPM Task Group Report 307: use of EPIDs for patient‐specific IMRT and VMAT QA
N Dogan, BJ Mijnheer, K Padgett… - Medical …, 2023 - Wiley Online Library
Purpose Electronic portal imaging devices (EPIDs) have been widely utilized for patient‐
specific quality assurance (PSQA) and their use for transit dosimetry applications is …
specific quality assurance (PSQA) and their use for transit dosimetry applications is …
Characterization of a novel two dimensional diode array the “magic plate” as a radiation detector for radiation therapy treatment
Purpose: Intensity modulated radiation therapy (IMRT) utilizes the technology of multileaf
collimators to deliver highly modulated and complex radiation treatment. Dosimetric …
collimators to deliver highly modulated and complex radiation treatment. Dosimetric …
The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy
G Nicolini, E Vanetti, A Clivio, A Fogliata, S Korreman… - Radiation …, 2008 - Springer
Background To expand and test the dosimetric procedure, known as GLAaS, for amorphous
silicon detectors to the RapidArc intensity modulated arc delivery with Varian infrastructures …
silicon detectors to the RapidArc intensity modulated arc delivery with Varian infrastructures …
Online pretreatment verification of high-dose rate brachytherapy using an imaging panel
GP Fonseca, M Podesta, M Bellezzo… - Physics in Medicine …, 2017 - iopscience.iop.org
Brachytherapy is employed to treat a wide variety of cancers. However, an accurate
treatment verification method is currently not available. This study describes a pre-treatment …
treatment verification method is currently not available. This study describes a pre-treatment …
Patient specific quality control for Stereotactic Ablative Body Radiotherapy (SABR): it takes more than one phantom
T Kron, E Ungureanu, R Antony… - Journal of Physics …, 2017 - iopscience.iop.org
Abstract Stereotactic Ablative Body Radiotherapy (SABR) is an extension of the concepts of
Stereotactic Radiosurgery from intracranial procedures to extracranial targets. This brings …
Stereotactic Radiosurgery from intracranial procedures to extracranial targets. This brings …
The influence of a novel transmission detector on 6 MV x-ray beam characteristics
S Venkataraman, KE Malkoske, M Jensen… - Physics in Medicine …, 2009 - iopscience.iop.org
The purpose of this work was to investigate the influence of a new transmission detector on
6 MV x-ray beam properties. The device, COMPASS (IBA Dosimetry, Germany), contains …
6 MV x-ray beam properties. The device, COMPASS (IBA Dosimetry, Germany), contains …
Initial evaluation of a commercial EPID modified to a novel direct‐detection configuration for radiotherapy dosimetry
Electronic portal imaging devices (EPIDs) integrated with medical linear accelerators utilize
an indirect‐detection EPID configuration (ID‐EPID). Amorphous silicon ID‐EPIDs provide …
an indirect‐detection EPID configuration (ID‐EPID). Amorphous silicon ID‐EPIDs provide …
The impact of MLC transmitted radiation on EPID dosimetry for dynamic MLC beams
The purpose of this study was to experimentally quantify the change in response of an
amorphous silicon electronic portal imaging device (EPID) to dynamic multileaf collimator …
amorphous silicon electronic portal imaging device (EPID) to dynamic multileaf collimator …
Comprehensive fluence model for absolute portal dose image prediction
K Chytyk, BMC McCurdy - Medical physics, 2009 - Wiley Online Library
Amorphous silicon electronic portal imaging devices (EPIDs) continue to be investigated as
treatment verification tools, with a particular focus on intensity modulated radiation therapy …
treatment verification tools, with a particular focus on intensity modulated radiation therapy …
Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool
M Iori, E Cagni, M Paiusco, P Munro… - Medical …, 2010 - Wiley Online Library
Purpose The electronic portal imaging device (EPID) is a system for checking the patient
setup; as a result of its integration with the linear accelerator and software customized for …
setup; as a result of its integration with the linear accelerator and software customized for …