Performances of C-BORD's tagged neutron inspection system for explosives and illicit drugs detection in cargo containers

A Sardet, B Perot, C Carasco, G Sannie… - … on Nuclear Science, 2021 - ieeexplore.ieee.org
In the frame of the effective Container inspection at BORDer control points (C-BORD) project
[H2020 program of the European Union (EU)], a Rapidly Relocatable Tagged Neutron …

Detection module of the C-BORD rapidly relocatable tagged neutron inspection system (RRTNIS)

F Pino, CL Fontana, G Nebbia, B Pedersen… - Nuclear Instruments and …, 2021 - Elsevier
This article reports a detailed description of the integration tests of the first Rapidly
Relocatable Tagged Neutron Inspection System (RRTNIS) carried out at the European …

Design of the rapidly relocatable tagged neutron inspection system of the C-BORD project

A Sardet, B Perot, C Carasco, G Sannié… - 2016 IEEE Nuclear …, 2016 - ieeexplore.ieee.org
Within the framework of the European H2020 C-BORD project, aiming at improving
container inspection technologies, a compact and “Rapidly Relocatable Tagged Neutron …

Measuring hydrogen with fast neutrons: application to organic materials identification in cargo containers

C Carasco, B Pérot, A Sardet - … and Methods in Physics Research Section …, 2020 - Elsevier
To inspect cargo containers, X-ray imaging can be complemented by fast neutron
interrogation to provide indication concerning the chemical nature of the transported goods …

Improving the sensitivity of fast neutron inelastic scatter analysis to iron using associated particle collimation

MR Abel, LH Nie - Nuclear Instruments and Methods in Physics Research …, 2019 - Elsevier
Purpose The purpose of this study is twofold; first, a prompt gamma-ray neutron activation
analysis (PGNAA) system will be constructed and employed in order to find the approximate …

Uncertainty Quantification in Emission Quantitative Imaging

A Bevill - 2017 - deepblue.lib.umich.edu
Imaging detectors have potential to improve the reliability of plutonium holdup
measurements. Holdup measurement is a significant challenge for nuclear safeguards and …

Source Correlated Prompt Neutron Activation Analysis for Material Identification and Localization

B Canion, S McConchie… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
This paper investigates the energy spectrum of photon signatures from an associated
particle imaging deuterium tritium (API-DT) neutron generator interrogating shielded …

[引用][C] АВТОМАТИЗАЦИЯ ЭНЕРГЕТИЧЕСКОЙ КАЛИБРОВКИ ГАММА-ДЕТЕКТОРОВ В УСТАНОВКАХ МЕЧЕНЫХ НЕЙТРОНОВ

РР Бестаев