Scanning Three-Dimensional X-ray Diffraction Microscopy with a Spiral Slit
Y Hayashi, D Setoyama, K Fukuda, K Okuda… - Quantum Beam …, 2023 - mdpi.com
Recently, nondestructive evaluation of the stresses localized in grains was achieved for
plastically deformed low-carbon steel using scanning three-dimensional X-ray diffraction …
plastically deformed low-carbon steel using scanning three-dimensional X-ray diffraction …
Double-Exposure Method with Synchrotron White X-ray for Stress Evaluation of Coarse-Grain Materials
K Suzuki, A Shiro, H Toyokawa, C Saji… - Quantum Beam Science, 2020 - mdpi.com
Stress measurements of coarse-grained material are difficult using synchrotron X-ray
diffraction because the diffraction patterns of coarse-grained materials are spotty. In addition …
diffraction because the diffraction patterns of coarse-grained materials are spotty. In addition …
In-operando Measurement of Internal Temperature and Stress in Lithium-ion Batteries
T Hirano, T Maeda, T Murata, T Yamaki… - SPring-8/SACLA …, 2023 - jstage.jst.go.jp
The temperature rise due to high current/power operations and stress caused by the
expansion or contraction of electrodes by lithium (de)-intercalation is known to be a …
expansion or contraction of electrodes by lithium (de)-intercalation is known to be a …
Evaluation of welding residual stresses using diffraction spot trace method
K Suzuki, T Shobu, A Shiro… - Advanced Materials …, 2014 - Trans Tech Publ
A diffraction spot trace method (DSTM) is very useful to measure internal stresses of
materials with coarse grains. In this study, validity of the DSTM was examined using high …
materials with coarse grains. In this study, validity of the DSTM was examined using high …
Residual Stress Analysis by Monochromatic High‐Energy X‐rays
RV Martins - … Radiation in Engineering Materials Science: From …, 2017 - Wiley Online Library
The chapter deals with residual stress analysis using monochromatic high‐energy
synchrotron radiation (angle dispersive setup). State of the art techniques for non …
synchrotron radiation (angle dispersive setup). State of the art techniques for non …
Stress measurements of coarse grain materials using double exposure method with hard synchrotron X-rays
K Suzuki, T Shobu, A Shiro - Materials Research Proceedings, 2018 - mrforum.com
The double exposure method (DEM) is proposed herein for X-ray stress measurement of
coarse grain materials. A diffraction angle was obtained from an incident beam and a spotty …
coarse grain materials. A diffraction angle was obtained from an incident beam and a spotty …
リチウムイオン電池内部の温度・応力分布のオペランド計測
平野辰巳, 前田壮宏, 村田徹行, 山木孝博… - SPring-8/SACLA 利用 …, 2023 - jstage.jst.go.jp
抄録 車載用リチウムイオン二次電池 (LIB) のサイクル時の劣化要因として, 高い電流レートにおける
電池内部の温度上昇, リチウムイオンの正負極間移動にともなう電極の膨張・収縮による応力など …
電池内部の温度上昇, リチウムイオンの正負極間移動にともなう電極の膨張・収縮による応力など …
リチウムイオン実電池の充放電中のオペランド二次元X 線回折計測
平野辰巳, 村田徹行, 松原英一郎, 菖蒲敬久… - SPring-8/SACLA 利用 …, 2021 - jstage.jst.go.jp
抄録 車載用リチウムイオン実電池 (LIB) のサイクル時の劣化要因として, 高い電流レートにおける
電池内部の温度上昇, リチウムイオンの正負極間移動にともなう電極の膨張・収縮による応力など …
電池内部の温度上昇, リチウムイオンの正負極間移動にともなう電極の膨張・収縮による応力など …
2 次元検出器を用いた応力測定法の現状と今後の展開2. 放射光を利用した2 次元検出器による応力評価の最前線
鈴木賢治, 菖蒲敬久 - 材料, 2015 - jstage.jst.go.jp
2次元検出器を用いた応力測定法の現状と今後の展開 Toggle navigation J-STAGE home 資料・記事
を探す 資料を探す:資料タイトルから 資料を探す:分野から 資料を探す:発行機関から 記事を探す データ …
を探す 資料を探す:資料タイトルから 資料を探す:分野から 資料を探す:発行機関から 記事を探す データ …