Short-circuit analysis of DER-based microgrids in connected and islanded modes of operation
N Simic, L Strezoski, B Dumnic - Energies, 2021 - mdpi.com
Since microgrids should be able to smoothly operate in two distinct modes—grid-connected
and islanded, their fault currents can widely fluctuate depending on the operational mode …
and islanded, their fault currents can widely fluctuate depending on the operational mode …
Construction of HILS System for LLC Resonant Converter Using LPV Model
H Funaki, Y Noge, M Shoyama… - IEEE Transactions …, 2023 - ieeexplore.ieee.org
HILS (Hardware-In-the-Loop Simulation) of SMPSs (Switched-Mode Power Supplies)
requires a high real-time simulation capability for the power stage emulator. However, it is …
requires a high real-time simulation capability for the power stage emulator. However, it is …
An investigation into the applications of real-time simulator in experimental validation of PMSM-based electric drive system
Permanent magnet synchronous motors find wide application in industrial as well as
transportation sector owing to its high efficiency, compactness and having high torque …
transportation sector owing to its high efficiency, compactness and having high torque …
Parameters Estimation of a 3-Phase AC-DC Converter based on the Digital Twin Method
G Di Nezio, SDL Diz, M Di Benedetto… - 2023 IEEE Energy …, 2023 - ieeexplore.ieee.org
Digital Twin (DT) technology is transforming the energy conversion industry by replicating
the behavior of physical systems with high fidelity in real-time. This paper presents a …
the behavior of physical systems with high fidelity in real-time. This paper presents a …
3-Phase Boost Rectifier Condition Health Monitoring based on Digital Twin Technique
G Di Nezio, M Di Benedetto, A Lidozzi… - … Conference on Clean …, 2023 - ieeexplore.ieee.org
In the field of energy generation from renewables, such as wind power, it is essential to
avoid service interruption, as well as to assure scheduled maintenance, in order to limit the …
avoid service interruption, as well as to assure scheduled maintenance, in order to limit the …
Real-time simulation method using LPV model of LLC current resonant converter
H Funaki, Y Noge, M Shoyama… - … (IPEC-Himeji 2022 …, 2022 - ieeexplore.ieee.org
In performing real-time simulation of electric circuits, the time step is constrained by the
computation, so there is a limit to be small it. In addition, when electric transient analysis …
computation, so there is a limit to be small it. In addition, when electric transient analysis …
Modelado y simulación de un control de convertidor CC-CC basándose en simuladores tipo Real Time Hardware In the Loop (RT-HIL)
Á Morales Muñoz - 2020 - oa.upm.es
El Objetivo de Desarrollo Sostenible (ODS) número 13 implora una reducción drástica de la
emisión de gases invernadero. Entre los sectores más contaminantes se encuentra el …
emisión de gases invernadero. Entre los sectores más contaminantes se encuentra el …
[引用][C] Visualizing Power-Quality Phenomena in a Hands-On Electric Power Systems Laboratory
TV Cook, RJ Kerestes, BM Grainger - 2019 ASEE Annual Conference & Exposition, 2019