[PDF][PDF] MIRD pamphlet no. 16: techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates

JA Siegel, SR Thomas, JB Stubbs… - Journal of Nuclear …, 1999 - Soc Nuclear Med
Theabsorbedradiationdosefrominternallyde… nuclides is a major factor in assessing risk
and therapeutic utility when evaluating new radiopharmaceuticals for use in nuclear …

Update: The Case for Patient-Specific Dosimetry in Radionuclide Therapy

MG Stabin - Cancer biotherapy & radiopharmaceuticals, 2008 - liebertpub.com
In this review of the literature and general practice in the use of radiopharmaceuticals for
therapy, an argument is provided to demonstrate that the use of patient-individualized …

Uncertainties in internal dose calculations for radiopharmaceuticals

MG Stabin - Journal of nuclear medicine, 2008 - Soc Nuclear Med
This paper presents a systematic analysis of the inherent uncertainty in internal dose
calculations for radiopharmaceuticals. A generic equation for internal dose is presented, and …

Accuracy of quantitative reconstructions in SPECT/CT imaging

S Shcherbinin, A Celler, T Belhocine… - Physics in Medicine …, 2008 - iopscience.iop.org
The goal of this study was to determine the quantitative accuracy of our OSEM-APDI
reconstruction method based on SPECT/CT imaging for Tc-99m, In-111, I-123, and I-131 …

Influence of high-energy photons on the spectrum of iodine-123 with low- and medium-energy collimators: consequences for imaging with 123I-labelled compounds …

AA Dobbeleir, ASE Hambÿe, PR Franken - European journal of nuclear …, 1999 - Springer
Using iodine-123 labelled radiotracers, the presence of 2.5% high-energy photons causes
image deterioration due to increased scatter. To investigate the influence of these photons …

Image quantification for radiation dose calculations—limitations and uncertainties

JM Pereira, MG Stabin, FRA Lima, M Guimarães… - Health …, 2010 - journals.lww.com
Radiation dose calculations in nuclear medicine depend on quantification of activity via
planar and/or tomographic imaging methods. However, both methods have inherent …

Effect of collimator choice on quantitative assessment of cardiac iodine 123 MIBG uptake

Y Inoue, A Suzuki, I Shirouzu, T Machida… - Journal of nuclear …, 2003 - Springer
Background Quantitative accuracy in iodine 123 studies may be impaired by septal
penetration. We evaluated the effect of collimator choice on estimation of the heart …

Absolute activity quantitation in simultaneous 123I/99mTc brain SPECT

G El Fakhri, SC Moore, P Maksud… - Journal of Nuclear …, 2001 - Soc Nuclear Med
Dual-isotope imaging can allow simultaneous assessment of brain perfusion using a 99mTc-
labeled tracer and neurotransmission using an 123I-labeled tracer. However, the images …

Collimator choice in cardiac SPECT with I-123-labeled tracers

Y Inoue, I Shirouzu, T Machida, Y Yoshizawa… - Journal of nuclear …, 2004 - Springer
Background Septal penetration of high-energy photons may degrade the quality of single
photon emission computed tomography (SPECT) of the heart with iodine 123-labeled …

Acquisition protocols and correction methods for estimation of the heart-to-mediastinum ratio in 123I-metaiodobenzylguanidine cardiac sympathetic imaging

Y Inoue, Y Abe, Y Itoh, Y Asano, K Kikuchi… - Journal of Nuclear …, 2013 - Soc Nuclear Med
Septal penetration of high-energy photons affects quantitative results in imaging of 123I-
labeled tracers. We investigated acquisition protocols (collimator choice and energy window …