A simulation study for dengue virus detection using surface plasmon resonance sensor heterostructure of silver, barium titanate, and cerium oxide
Surface plasmon resonance (SPR) sensor devices accommodate immense capability for
several applications in monitoring and detecting the progress of a disease. SPR sensors are …
several applications in monitoring and detecting the progress of a disease. SPR sensors are …
Early Detection of Chikungunya Virus Utilizing the Surface Plasmon Resonance Comprising a Silver-Silicon-PtSe2 Multilayer Structure
TI Singh, P Singh, B Karki - Plasmonics, 2023 - Springer
The sensing performance parameters of the SPR sensors are sensitivity, detection accuracy,
the figure of merit (FOM), and full-width half maximum (FWHM), and it has been discussed …
the figure of merit (FOM), and full-width half maximum (FWHM), and it has been discussed …
Black phosphorous and cytop nanofilm‐based long‐range SPR sensor with enhanced quality factor
This numerical work proposes two novel designs of long‐range surface plasmon resonance
sensors (LRSPR) using two different coupling prisms. The performance analysis of the …
sensors (LRSPR) using two different coupling prisms. The performance analysis of the …
Detecting binary mixtures of sulfolane with ethylene glycol, diethylene glycol, and polyethylene glycol in water using surface plasmon resonance sensor: a numerical …
This work offers a quite sensitive SPR-based sensor with a new heterostructure based on
platinum and ITO using silver as the plasmonic metal to examine the detection of sulfolane …
platinum and ITO using silver as the plasmonic metal to examine the detection of sulfolane …
A theoretical analysis of refractive index sensor with improved sensitivity using titanium dioxide, graphene, and antimonene grating: Pseudomonas bacteria detection
A surface plasmon resonance (SPR) based biosensor is proposed to detect Pseudomonas
bacteria. The sensor design consists of two silvers (Ag), a Titanium dioxide (TiO 2) …
bacteria. The sensor design consists of two silvers (Ag), a Titanium dioxide (TiO 2) …
Fluorinated graphene and CNT-based surface plasmon resonance sensor for detecting the viral particles of SARS-CoV-2
Due to the ability to distinguish between infected and uninfected individuals, the continuing
highly contagious Coronavirus disease pandemic, which is brought on by the severe acute …
highly contagious Coronavirus disease pandemic, which is brought on by the severe acute …
Plasmonic pregnancy detector: enhancing sensitivity with SPR sensor
Detecting biomolecular interactions without labeling has become possible because of
surface plasmon resonance (SPR) sensing development. In this work, we report on …
surface plasmon resonance (SPR) sensing development. In this work, we report on …
Surface plasmon resonance biosensor sensitivity improvement employing of 2D materials and BaTiO3 with bimetallic layers of silver
In this paper, a surface plasmon resonance (SPR) biosensor built on bimetallic layers of
Silver, BaTiO3, and transition metal dichalcogenide material (MoS2/MoSe2/WS2/WSe2) are …
Silver, BaTiO3, and transition metal dichalcogenide material (MoS2/MoSe2/WS2/WSe2) are …
Creatinine detection by surface plasmon resonance sensor using layers of cerium oxide and graphene over conventional Kretschmann configuration
In this study, creatinine in solutions at varied concentrations (non-enzymatic samples) is
detected utilizing a surface plasmon resonance (SPR) sensor design. The presence of …
detected utilizing a surface plasmon resonance (SPR) sensor design. The presence of …
Detection of Chikungunya Virus Using Tantalum Diselenide (TaSe2)-Based Surface Plasmon Resonance Biosensor
In our current study, silver (Ag) as a noble metal and tantalum diselenide (TaSe2) material
are used in the proposed SPR biosensor to detect the chikungunya virus. To increase the …
are used in the proposed SPR biosensor to detect the chikungunya virus. To increase the …