A review of the dense Z-pinch
MG Haines - Plasma Physics and Controlled Fusion, 2011 - iopscience.iop.org
The Z-pinch, perhaps the oldest subject in plasma physics, has achieved a remarkable
renaissance in recent years, following a few decades of neglect due to its basically unstable …
renaissance in recent years, following a few decades of neglect due to its basically unstable …
[HTML][HTML] Update on the scientific status of the plasma focus
S Auluck, P Kubes, M Paduch, MJ Sadowski, VI Krauz… - Plasma, 2021 - mdpi.com
This paper is a sequel to the 1998 review paper “Scientific status of the Dense Plasma
Focus” with 16 authors belonging to 16 nations, whose initiative led to the establishment of …
Focus” with 16 authors belonging to 16 nations, whose initiative led to the establishment of …
Plasma focus as a possible x-ray source for radiography
A study of x-ray emission from a low energy (1.8 kJ) plasma focus (PF) device powered by a
9 µF capacitor bank, charged at 20 kV and giving peak discharge current of about 175 kA by …
9 µF capacitor bank, charged at 20 kV and giving peak discharge current of about 175 kA by …
Correlated deuteron energy spectra and neutron yield for a 3 kJ plasma focus
A magnetic spectrometer positioned on the axis of a 3 kJ plasma focus device has been
used to measure energy spectra of deuterons emitted from the pinch region of the focus …
used to measure energy spectra of deuterons emitted from the pinch region of the focus …
Scope of plasma focus with argon as a soft X-ray source
M Zakaullah, K Alamgir, M Shafiq… - IEEE transactions on …, 2002 - ieeexplore.ieee.org
The X-radiation emission from a low energy plasma focus with argon as a filling gas is
investigated. Specifically, the attention is paid to determine the system efficiency for argon K …
investigated. Specifically, the attention is paid to determine the system efficiency for argon K …
Spectral study of the electron beam emitted from a 3 kJ plasma focus
A Patran, LC Tan, D Stoenescu… - Plasma Sources …, 2005 - iopscience.iop.org
In a 3 kJ Mather-type plasma focus device operated in neon, the electron beam emission is
investigated using both a magnetic electron energy analyser (in the 30–660 keV range) and …
investigated using both a magnetic electron energy analyser (in the 30–660 keV range) and …
Study of neutron emission in a low-energy plasma focus with β-source-assisted breakdown
The influence of pre-ionization around the insulator sleeve of plasma focus, by a mesh-type
β-source 28 Ni 63 on neutron emission is investigated. The experiment is conducted on two …
β-source 28 Ni 63 on neutron emission is investigated. The experiment is conducted on two …
Low-energy plasma focus as a tailored X-ray source
Abstract A low-energy (2.3 kJ) plasma focus energized by a single 32-μF capacitor charged
at 12 kV with filling gases hydrogen, neon, and argon is investigated as an X-ray source …
at 12 kV with filling gases hydrogen, neon, and argon is investigated as an X-ray source …
Compact sub-kilojoule range fast miniature plasma focus as portable neutron source
As a first step toward the development of a compact and portable, quasi-continuous pulsed
neutron source, we have demonstrated a'fast miniature plasma focus (PF) device'as a …
neutron source, we have demonstrated a'fast miniature plasma focus (PF) device'as a …
Plasma focus as a high intensity flash X-ray source for biological radiography
A study on X-ray emission from a low energy (3.3 kJ) plasma focus (PF) device operated
with hydrogen is reported. X-ray are detected by using an X-ray detector consisting of three …
with hydrogen is reported. X-ray are detected by using an X-ray detector consisting of three …