Electrical resistivity of sandy soil

LMS Pandey, SK Shukla, D Habibi - Géotechnique Letters, 2015 - icevirtuallibrary.com
This paper presents the results of an investigation into the interaction between the various
electrical factors pertaining to resistivity tests in Perth sandy soil (specifically AC input …

Compaction verification of lateritic soil using electrical resistivity: a laboratory study

F Owusu-Nimo, D Peprah-Manu, FJ Ayeh… - Geotechnical and …, 2024 - Springer
Constructing road pavement and highways in tropical countries usually requires using
lateritic soils as pavement material. The degree of compaction during the placement of these …

Laboratory investigation of GCL performance for covering arsenic contaminated mine wastes

RK Rowe, MS Hosney - Geotextiles and Geomembranes, 2013 - Elsevier
The performance of three geosynthetic clay liners (GCLs) above arsenic-bearing gold mine
tailings is examined based on a series of laboratory column experiments conducted over a …

Geo-electrical characterization of physical and mechanical properties of zinc tailing

V Wayal, TG Sitharam, M Anjali - Journal of Applied Geophysics, 2021 - Elsevier
In the present study, an attempt is made to characterize the tailing material using the
electrical resistivity method through a series of laboratory experiments. Tailing materials are …

Effect of salt and NAPL on electrical resistivity of fine-grained soil-sand mixtures

PK Kolay, SG Burra, S Kumar - International Journal of …, 2018 - Taylor & Francis
Electrical resistivity of soils are very important for various engineering projects, for example,
subsurface transmission of either heated fluids or high-voltage buried power cables; storage …

Detection of landfill cover damage using geophysical methods

F Genelle, C Sirieix, J Riss, V Naudet… - Near Surface …, 2014 - earthdoc.org
In closed hazardous waste (ie industrial) landfills, impermeable covers are used to seal in
the waste so as to minimise water infiltration and the accumulation of leachate inside the …

Inversion of synthetic and measured 3D geoelectrical data to study the geomembrane below a landfill

A Aguzzoli, A Fumagalli, A Scotti, L Zanzi… - 4th Asia Pacific Meeting …, 2021 - earthdoc.org
The aim of this work is to explore the potential of ERT to study the geometry and soundness
of the geomembrane that is commonly placed below the waste deposits to prevent leachate …

Optimum reduction of sensing electrodes for delamination identification with electrical resistance tomography

LW Escalona‐Galvis… - Structural Control and …, 2021 - Wiley Online Library
Electrical resistance tomography (ERT) is a non‐destructive evaluation (NDE) technique that
measures the voltages when electric current is injected in a body where damage induced …

Studies on electrical resistivity of Perth sand

FA Kuranchie, SK Shukla, D Habibi… - International Journal of …, 2014 - Taylor & Francis
This paper presents experimental and numerical studies on electrical resistivity of Perth
sand in its very loose state to very dense state. A simple laboratory experimental setup was …

Using stress wave technology for leakage detection in a landfill impervious layer

Y Chen, H Sun, W Zhang, X Huang - Environmental Science and Pollution …, 2019 - Springer
This paper proposes a stress wave monitoring method for monitoring and locating leakage
through the impervious layer at a landfill to resolve the “first pollution, then discovery” …