Harmonic Analysis of the Trapezoidal Waves in the Power Quality Issues

T Halder - 2020 IEEE 17th India Council International …, 2020 - ieeexplore.ieee.org
The paper presents that the harmonic analysis is completely accomplished by the Fourier
series to find out total harmonic distortion (THD) and harmonic weightings of the trapezoidal …

Reconfiguration distribution network with ant colony

JG Daud, M Kondoj, M Patabo - 2018 International Conference …, 2018 - ieeexplore.ieee.org
Harmonics is one of the disturbances in electrical quality that directly affects the increase in
power losses in the distribution network. This is because more and more customers use non …

Analysis and mitigation of harmonics for Standard IEEE 13 bus test system using ETAP

LG Mahiwal, JG Jamnani - 2019 International Conference on …, 2019 - ieeexplore.ieee.org
The main intension of any electrical utility company is to deliver power with best quality. By
expanding the utilization of power electronic gadgets (nonlinear loads), sinusoidal …

Analyzing fast charger in the smart grid from power quality's prospecting

B Arabsalmanabadi, A Javadi… - IECON 2017-43rd …, 2017 - ieeexplore.ieee.org
Going forward to reach infrastructure grid by incorporating cluster of renewable and
distributed energy sources, storage systems, different kinds of loads, in a huge dimension of …

Determination of Optimal Locations and Parameters of Passive Harmonic Filters in Unbalanced Systems Using the Multiobjective Genetic Algorithm

MJ Milovanovic, SS Raicevic, DO Klimenta… - Elektronika ir …, 2024 - eejournal.ktu.lt
This paper discusses the problem of optimal placement and sizing of passive harmonic
filters to mitigate harmonics in unbalanced distribution systems. The problem is formulated …

Control of series connected VSC modules for UHVDC application

X Fu, LA Dessaint, A Javadi… - IECON 2017-43rd …, 2017 - ieeexplore.ieee.org
As HVDC based on voltage source converter (VSC) technology has already reached 350
kVdc voltage level, this paper examines the feasibility of connecting four voltage source …

Comparative analysis between Backstepping, Sliding mode and PI control applied to Shunt Active Filter

B Deffaf, F Hamoudi, N Debdouche… - 2022 2nd International …, 2022 - ieeexplore.ieee.org
The main objective of this paper is a comparative analysis between three well-known control
techniques applied to active power filters, namely backstepping, sliding mode, and PI …

A hybrid series active filter using single-phase low rating packed u-cell converter

A Javadi, X Fu, A Hamadi… - IECON 2018-44th Annual …, 2018 - ieeexplore.ieee.org
In this research paper, the authors propose single-phase Transformerless Hybrid Series
Active Filter called a THSeAF based on a seven-level Packed U-Cell converter (PUC) to …

[PDF][PDF] Performance analysis of power flow strategies adjusted to a distribution network with non-linear loads and a PV system

A Martínez-Peñaloza, G Osma-Pinto, G Ordoñez-Plata - RE&PQJ, 2022 - researchgate.net
In analysing power flows, computational strategies and tools are used to study electrical
networks considered illconditioned by characteristics such as radial topology, load …

Power Quality Conditioning due to Flickering Loads with Shunt Active Power Filter using Fuzzy-Granular Controller Method

NMS Hannoon, DVN Ananth, N Hiday… - … in Advances in …, 2021 - ieeexplore.ieee.org
This paper proposes the modeling and analysis of a three-phase four wire Shunt Active
Power Filter (SHAF) based on real and reactive power (PQ) control method for power quality …