Report of AAPM task group 235 radiochromic film dosimetry: an update to TG‐55
A Niroomand‐Rad, ST Chiu‐Tsao, MP Grams… - Medical …, 2020 - Wiley Online Library
The use of radiochromic film (RCF) dosimetry in radiation therapy is extensive due to its high
level of achievable accuracy for a wide range of dose values and its suitability under a …
level of achievable accuracy for a wide range of dose values and its suitability under a …
Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification …
Purpose The need for dosimetric accuracy in external beam radiotherapy is well established
[1, 2]. A standard requirement of the combined uncertainties in absorbed dose delivery is …
[1, 2]. A standard requirement of the combined uncertainties in absorbed dose delivery is …
Verification of high dose rate brachytherapy dose distributions with EBT3 Gafchromic film quality control techniques
It is essential that quality control (QC) techniques are developed to keep pace with modern
high dose rate (HDR) brachytherapy. Current QC methods may be insufficient to fully assure …
high dose rate (HDR) brachytherapy. Current QC methods may be insufficient to fully assure …
Comparison of planned and measured rectal dose in-vivo during high dose rate Cobalt-60 brachytherapy of cervical cancer
Abstract Cobalt-60 (Co-60) is a relatively new source for the application of high-dose rate
(HDR) brachytherapy. Radiation dose to the rectum is often a limiting factor in achieving the …
(HDR) brachytherapy. Radiation dose to the rectum is often a limiting factor in achieving the …
Dose error from deviation of dwell time and source position for high dose-rate 192Ir in remote afterloading system
H Okamoto, A Aikawa, A Wakita… - Journal of radiation …, 2014 - academic.oup.com
The influence of deviations in dwell times and source positions for 192Ir HDR-RALS was
investigated. The potential dose errors for various kinds of brachytherapy procedures were …
investigated. The potential dose errors for various kinds of brachytherapy procedures were …
Optimum radiation source for radiation therapy of skin cancer
H Safigholi, WY Song… - Journal of applied clinical …, 2015 - Wiley Online Library
Several different applicators have been designed for treatment of skin cancers, such as
scalp, hand, and legs using Ir‐192 HDR brachytherapy sources (IR‐HDRS), miniature …
scalp, hand, and legs using Ir‐192 HDR brachytherapy sources (IR‐HDRS), miniature …
[HTML][HTML] In-vivo Comparison of Planned and Measured Rectal Doses during Cobalt-60 HDR CT-based Intracavitary Brachytherapy Applications of Cervical Cancer …
SK Johan, D Lobo, MS Athiyamaan… - Asian Pacific journal …, 2023 - ncbi.nlm.nih.gov
Background: A semiconductor rectal probe was used to compare planned and measured
rectal doses during Co-60 high dose rate (HDR) CT-based intracavitary brachytherapy …
rectal doses during Co-60 high dose rate (HDR) CT-based intracavitary brachytherapy …
Characterization of GafChromic EBT2 film dose measurements using a tissue-equivalent water phantom for a Theratron® Equinox Cobalt-60 teletherapy machine
DA Addo, EE Kaufmann, SN Tagoe, AK Kyere - Plos one, 2022 - journals.plos.org
Purpose In vivo dosimetry is a quality assurance tool that provides post-treatment
measurement of the absorbed dose as delivered to the patient. This dosimetry compares the …
measurement of the absorbed dose as delivered to the patient. This dosimetry compares the …
Film based verification of calculation algorithms used for brachytherapy planning-getting ready for upcoming challenges of MBDCA
G Zwierzchowski, G Bielęda, J Skowronek… - Journal of Contemporary …, 2016 - termedia.pl
Purpose: Well-known defect of TG-43 based algorithms used in brachytherapy is a lack of
information about interaction cross-sections, which are determined not only by electron …
information about interaction cross-sections, which are determined not only by electron …
Monte Carlo‐based investigation of absorbed‐dose energy dependence of radiochromic films in high energy brachytherapy dosimetry
M Subhalaxmi, TP Selvam - Journal of Applied Clinical Medical …, 2014 - Wiley Online Library
Relative absorbed dose energy response correction, R, for various radiochromic films in
water phantom is calculated by the use of the Monte Carlo‐based EGSnrc code system for …
water phantom is calculated by the use of the Monte Carlo‐based EGSnrc code system for …