Roadmap for metal nanoparticles in radiation therapy: Current status, translational challenges, and future directions
J Schuemann, AF Bagley, R Berbeco… - Physics in Medicine …, 2020 - iopscience.iop.org
This roadmap outlines the potential roles of metallic nanoparticles (MNPs) in the field of
radiation therapy. MNPs made up of a wide range of materials (from Titanium, Z= 22, to …
radiation therapy. MNPs made up of a wide range of materials (from Titanium, Z= 22, to …
Wash‐free fluorescent tools based on organic molecules: Design principles and biomedical applications
J Tan, C Wang, Z Hu, X Zhang - Exploration, 2024 - Wiley Online Library
Fluorescence‐assisted tools based on organic molecules have been extensively applied to
interrogate complex biological processes in a non‐invasive manner with good sensitivity …
interrogate complex biological processes in a non‐invasive manner with good sensitivity …
Robust multimaterial decomposition of spectral CT using convolutional neural networks
Z Chen, L Li - Optical Engineering, 2019 - spiedigitallibrary.org
Spectral computed tomography (CT) can reconstruct scanned objects at different energy-
bins and thus solve the multimaterial decomposition (MMD) problem. Because the linear …
bins and thus solve the multimaterial decomposition (MMD) problem. Because the linear …
Full-field in vivo imaging of nanoparticles using benchtop cone-beam XFCT system with pixelated photon counting detector
L Li, S Zhang, W Zhang, H Lu - Physics in Medicine & Biology, 2023 - iopscience.iop.org
Objective. X-ray fluorescence computed tomography (XFCT) is a promising noninvasive
technique for in vivo imaging of high-Z elements (eg gadolinium (Gd) or gold (Au)). In this …
technique for in vivo imaging of high-Z elements (eg gadolinium (Gd) or gold (Au)). In this …
An accurate probabilistic model with detector resolution and Doppler broadening correction in list-mode MLEM reconstruction for Compton camera
C Wu, S Zhang, L Li - Physics in Medicine & Biology, 2022 - iopscience.iop.org
Objective. The Compton cameras have been researched for medical applications and
radioactive material detection. It is challenging for the Compton camera to realize high …
radioactive material detection. It is challenging for the Compton camera to realize high …
First demonstration of Compton camera used for X-ray fluorescence imaging
C Wu, L Li - IEEE Transactions on Medical Imaging, 2022 - ieeexplore.ieee.org
X-ray fluorescence computed tomography (XFCT) is a promising approach used for
obtaining the distribution of high-Z elements in the target object. The characteristic energy of …
obtaining the distribution of high-Z elements in the target object. The characteristic energy of …
Characterization of a pixelated cadmium telluride detector system using a polychromatic X-ray source and gold nanoparticle-loaded phantoms for benchtop X-ray …
Pixelated semi-conductor detectors providing high energy resolution enable parallel
acquisition of x-ray fluorescence (XRF) signals, potentially leading to performance …
acquisition of x-ray fluorescence (XRF) signals, potentially leading to performance …
Reconstruction of x-ray fluorescence computed tomography from sparse-view projections via L1-norm regularized EM algorithm
X-ray fluorescence computed tomography (XFCT) as a molecular imaging modality can
simultaneously identify the localization and quantify the concentration of high-atomic …
simultaneously identify the localization and quantify the concentration of high-atomic …
A Monte Carlo model of a benchtop X-ray fluorescence computed tomography system and its application to validate a deconvolution-based X-ray fluorescence signal …
MF Ahmed, S Yasar, SH Cho - IEEE transactions on medical …, 2018 - ieeexplore.ieee.org
In this study, we developed and validated a Geant4-based Monte Carlo (MC) model of an
experimental benchtop X-ray fluorescence (XRF) computed tomography (XFCT) system for …
experimental benchtop X-ray fluorescence (XRF) computed tomography (XFCT) system for …
[PDF][PDF] 针孔X 射线荧光CT 探测角度优化研究
郭静, 冯鹏, 邓露珍, 罗燕, 何鹏, 魏彪 - Acta Optica Sinica, 2020 - researching.cn
摘要在管激发X 射线荧光CT (XFCT) 成像研究中, 探测角度与系统背景噪声, 探测灵敏度,
信噪比等参数密切相关. 鉴于此, 基于Geant4 设计一套多针孔准直管激发XFCT 成像系统 …
信噪比等参数密切相关. 鉴于此, 基于Geant4 设计一套多针孔准直管激发XFCT 成像系统 …