[HTML][HTML] An enhanced phase-locked loop for non-ideal grids combining linear active disturbance controller with moving average filter
Z Pan, X Wang, TTG Hoang, L Tian - … Journal of Electrical Power & Energy …, 2023 - Elsevier
Aiming at the accuracy deterioration of the synchronous reference frame phase-locked loop
(SRF-PLL) caused by the non-ideal grid conditions and the limitation of phase-locked loop …
(SRF-PLL) caused by the non-ideal grid conditions and the limitation of phase-locked loop …
A variable step size robust least mean logarithmic square-based control scheme for improved power quality of grid-interfaced PV system
Power Quality (PQ) issue has always been a challenge for Grid-Interfaced PV Systems
(GIPS). A novel Variable Step Size Robust Least Mean Logarithmic Square (VSS-RLMLS) …
(GIPS). A novel Variable Step Size Robust Least Mean Logarithmic Square (VSS-RLMLS) …
Improved MSTOGI-PLL with enhanced control under non-ideal grid voltage conditions
JH Zhu, P Zhang, L Tan, J Gu, H Li - Electric Power Systems Research, 2025 - Elsevier
Integration structure of second-and third-order generalized integrator phase-locking loop
(MSTOGI-PLL) has received attention for the processing ability of harmonics and DC bias …
(MSTOGI-PLL) has received attention for the processing ability of harmonics and DC bias …
A Quasi open‐loop robust three‐phase grid‐synchronization technique for non‐ideal grid
Abstract Development of advanced grid‐synchronization technique for unbalanced and
distorted grid is considered in this paper. In this context, self‐tuning filter (STF) is considered …
distorted grid is considered in this paper. In this context, self‐tuning filter (STF) is considered …
A Reliable Level-1 Onboard Charger of a Light Electric Vehicle for Smart Homes with Seamless Transition Capability
Level-1 charging of an LEV in a smart home is studied in this work. The performance of a
two-stage isolated OBC (onboard charger) under different modes of operation is discussed …
two-stage isolated OBC (onboard charger) under different modes of operation is discussed …
Analysis of Three-Phase Grid Synchronization Algorithms Performance Under Harmonic Pollution to Grid Voltage
VKI Caesarista, I Setiawan… - 2024 4th International …, 2024 - ieeexplore.ieee.org
The goal of this research is to assess the effectiveness of three-phase PLL algorithms when
exposed to harmonic pollution in the grid voltage. Grid synchronization is a crucial aspect …
exposed to harmonic pollution in the grid voltage. Grid synchronization is a crucial aspect …
[PDF][PDF] Grid Synchronization in a 3-Phase Inverter using Double Integration Method
Distributed renewable energy sources (DRESs) have additional benefits compared with
conventional fossil fuel-based energy sources. These sources are connected to the utility …
conventional fossil fuel-based energy sources. These sources are connected to the utility …
A Sigmoid Least Mean Fourth based Control Scheme for a Single-Stage Grid-Tied PV System
In a single-stage grid-tied PV system, the Voltage Source Inverter (VSI) performs the task of
MPPT along with delivery of high quality power to the grid. However, the presence of non …
MPPT along with delivery of high quality power to the grid. However, the presence of non …