Intensity-modulated arc therapy: principles, technologies and clinical implementation

XY Cedric, G Tang - Physics in Medicine & Biology, 2011 - iopscience.iop.org
Intensity-modulated arc therapy (IMAT) was proposed by Yu (1995 Phys. Med. Biol. 40 1435–
49) as an alternative to tomotherapy. Over more than a decade, much progress has been …

Volumetric modulated arc radiotherapy for carcinomas of the oro-pharynx, hypo-pharynx and larynx: a treatment planning comparison with fixed field IMRT

E Vanetti, A Clivio, G Nicolini, A Fogliata… - Radiotherapy and …, 2009 - Elsevier
PURPOSE: A planning study was performed to evaluate the performance of volumetric
modulated arc radiotherapy on head and neck cancer patients. Conventional fixed field …

Patient QA systems for rotational radiation therapy: a comparative experimental study with intentional errors

A Fredh, JB Scherman, LS Fog… - Medical …, 2013 - Wiley Online Library
Purpose: The purpose of the present study was to investigate the ability of commercial
patient quality assurance (QA) systems to detect linear accelerator‐related errors. Methods …

Patient‐specific quality assurance method for VMAT treatment delivery

E Schreibmann, A Dhabaan, E Elder, T Fox - Medical physics, 2009 - Wiley Online Library
Volumetric modulated arc therapy (VMAT) is a system for intensity‐modulated radiotherapy
treatment delivery that achieves high dose conformality by optimizing the dose rate, gantry …

Penalization of aperture complexity in inversely planned volumetric modulated arc therapy

KC Younge, MM Matuszak, JM Moran… - Medical …, 2012 - Wiley Online Library
Purpose: Apertures obtained during volumetric modulated arc therapy (VMAT) planning can
be small and irregular, resulting in dosimetric inaccuracies during delivery. Our purpose is to …

Simultaneous integrated boost radiotherapy for bilateral breast: a treatment planning and dosimetric comparison for volumetric modulated arc and fixed field intensity …

G Nicolini, A Clivio, A Fogliata, E Vanetti, L Cozzi - Radiation Oncology, 2009 - Springer
Purpose A study was performed comparing dosimetric characteristics of volumetric
modulated arcs (RapidArc, RA) and fixed field intensity modulated therapy (IMRT) on …

Gamma index comparison of three VMAT QA systems and evaluation of their sensitivity to delivery errors

L Vieillevigne, J Molinier, T Brun, R Ferrand - Physica medica, 2015 - Elsevier
Purpose To compare detectors for dosimetric verification before VMAT treatments and
evaluate their sensitivity to errors. Methods and materials Measurements using three …

Treatment plan complexity metrics for predicting IMRT pre-treatment quality assurance results

SB Crowe, T Kairn, J Kenny, RT Knight, B Hill… - Australasian physical & …, 2014 - Springer
The planning of IMRT treatments requires a compromise between dose conformity
(complexity) and deliverability. This study investigates established and novel treatment …

EPID dosimetry for pretreatment quality assurance with two commercial systems

DW Bailey, L Kumaraswamy, M Bakhtiari… - Journal of applied …, 2012 - Wiley Online Library
This study compares the EPID dosimetry algorithms of two commercial systems for
pretreatment QA, and analyzes dosimetric measurements made with each system alongside …

Cranio-spinal irradiation with volumetric modulated arc therapy: a multi-institutional treatment experience

A Fogliata, S Bergström, I Cafaro, A Clivio… - Radiotherapy and …, 2011 - Elsevier
PURPOSE: To report the treatment of cranio-spinal irradiation (CSI) with volumetric
modulated arc therapy (RapidArc) in adults and a child. MATERIALS AND METHODS: Five …