Flexible 3D architectured piezo/thermoelectric bimodal tactile sensor array for E‐skin application
P Zhu, Y Wang, Y Wang, H Mao… - Advanced Energy …, 2020 - Wiley Online Library
Electronic skin (e‐skin) functions as human–machines interaction interfaces, holding great
promise in future personal health monitoring and endowing robots with capability of sense of …
promise in future personal health monitoring and endowing robots with capability of sense of …
Applications of thermoresistive sensors using the electric equivalence principle
RCS Freire, SYC Catunda… - IEEE transactions on …, 2009 - ieeexplore.ieee.org
In this paper, a survey on the characteristics of thermoresistive sensors [positive temperature
coefficient (PTC) and negative temperature coefficient (NTC)] and their applications to …
coefficient (PTC) and negative temperature coefficient (NTC)] and their applications to …
Systematic design of micro-resistors for temperature control by quasi-simultaneous heating and temperature sensing
C Falconi - Sensors and Actuators B: Chemical, 2013 - Elsevier
A single resistor can be used for quasi-simultaneously heating and temperature sensing. For
instance, in microsystems this strategy is often employed for temperature control, flow …
instance, in microsystems this strategy is often employed for temperature control, flow …
Sensitivity analysis and automatic adjustment of a controlled-temperature thermoresistive-based anemometer
VSG Martins, RCS Freire… - 2012 IEEE International …, 2012 - ieeexplore.ieee.org
This paper presents an architecture of a hot-wire anemometer that adjusts the difference
between the sensor temperature and the fluid temperature and maximizes the sensitivity of …
between the sensor temperature and the fluid temperature and maximizes the sensitivity of …
A controlled-temperature hot-wire anemometer with voltage feedback linearization
LV Araujo, SYC Catunda, CET Dórea… - 2014 IEEE …, 2014 - ieeexplore.ieee.org
This paper proposes a new architecture of a controlled-temperature hot-wire anemometer
using voltage feedback linearization. The voltage feedback linearizes the sensor input …
using voltage feedback linearization. The voltage feedback linearizes the sensor input …
SPICE-based dynamical model of a NTC thermoresistive sensor for anemometer applications
LV Araujo, SYC Catunda, D Belfort… - 2015 IEEE …, 2015 - ieeexplore.ieee.org
In this paper a new analog behavioral model of a negative temperature coefficient
thermoresistive sensor developed using SPICE for a hot-wire Wheatstone-Bridge Constant …
thermoresistive sensor developed using SPICE for a hot-wire Wheatstone-Bridge Constant …
Architecture of an Electrical Equivalence Pyranometer with Temperature Difference Analog Control
ECS Dantas, JTD Segundo, SYC Catunda, DR Belfort… - Sensors, 2022 - mdpi.com
In this paper, an architecture of an electrical equivalence pyranometer with analog control of
the temperature difference is presented. The classical electrical equivalence pyranometer …
the temperature difference is presented. The classical electrical equivalence pyranometer …
Output dynamic range of radiometers based on thermoresistive sensors
VM Nascimento, TLVN Silva… - 2014 IEEE …, 2014 - ieeexplore.ieee.org
Thermo-resistive sensors are widely used in metrology and instrumentation systems. In the
case of radiometers used in measurement of solar radiation, the classical architecture uses …
case of radiometers used in measurement of solar radiation, the classical architecture uses …
[PDF][PDF] Precision active bridge circuit for measuring incremental resistance with ANN compensation of excitation voltage variation
The present work deals with the development of low cost, appreciably accurate precision
electronic circuit for resistive sensor where measurement of the incremental resistance …
electronic circuit for resistive sensor where measurement of the incremental resistance …
Analysis of the Wheatstone Bridge Radiometer Performance Dependence on the Ambient Temperature
JTD Segundo, ECS Dantas… - 2021 5th …, 2021 - ieeexplore.ieee.org
In this paper it is analysed the performance dependence on the ambient temperature of the
constant temperature Wheatstone Bridge architecture for a radiometer. The parameters …
constant temperature Wheatstone Bridge architecture for a radiometer. The parameters …