Review of non-invasive glucose sensing techniques: optical, electrical and breath acetone
M Shokrekhodaei, S Quinones - Sensors, 2020 - mdpi.com
Annual deaths in the US attributed to diabetes are expected to increase from 280,210 in
2015 to 385,840 in 2030. The increase in the number of people affected by diabetes has …
2015 to 385,840 in 2030. The increase in the number of people affected by diabetes has …
[图书][B] Handbook of optical sensing of glucose in biological fluids and tissues
VV Tuchin - 2008 - taylorfrancis.com
Although noninvasive, continuous monitoring of glucose concentration in blood and tissues
is one of the most challenging areas in medicine, a wide range of optical techniques has …
is one of the most challenging areas in medicine, a wide range of optical techniques has …
Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography
TL Chen, YL Lo, CC Liao… - Journal of biomedical …, 2018 - spiedigitallibrary.org
A method is proposed for determining the glucose concentration on the human fingertip by
extracting two optical parameters, namely the optical rotation angle and the depolarization …
extracting two optical parameters, namely the optical rotation angle and the depolarization …
In vivo Near-infrared noninvasive glucose measurement and detection in humans
T Han, J Liu, R Liu, W Chen, M Yao, X Liu… - Applied …, 2022 - journals.sagepub.com
In optical noninvasive glucose detection, how to detect the glucose-caused signals from the
constant human variations and disturbed probing conditions is always the biggest …
constant human variations and disturbed probing conditions is always the biggest …
In vitro studies toward noninvasive glucose monitoring with optical coherence tomography
We use optical coherence tomography (OCT) to measure glucose-induced changes in
Intralipid and in mouse skin samples in vitro. Mouse skin samples are cultured in a CO2 …
Intralipid and in mouse skin samples in vitro. Mouse skin samples are cultured in a CO2 …
Effect of photons of different scattering orders on the formation of a signal in optical low-coherence tomography of highly scattering media
MY Kirillin, IV Meglinskii, AV Priezzhev - Quantum Electronics, 2006 - iopscience.iop.org
The influence of photons of different scattering orders on the formation of a detected signal
in optical low-coherence tomography (OCT) is considered. The scattering orders are …
in optical low-coherence tomography (OCT) is considered. The scattering orders are …
Optical sensing of titanium dioxide nanoparticles within horny layer of human skin and their protecting effect against solar UV radiation
In the present paper the problem of protection of human skin against harmful UV solar rays
using nano-sized spherical particles of titanium dioxide and sensing their concentration if …
using nano-sized spherical particles of titanium dioxide and sensing their concentration if …
Three-dimensional correlation method for non-invasive blood glucose monitoring with optical coherence tomography
Y Su, K Cai, J Sun, P Hao, Y Zhang, Y Dong… - Optics and Lasers in …, 2025 - Elsevier
Optical non-invasive glucose monitoring (NIGM) is attractive to diabetes patients and
medical professionals due to its advantages of painlessness, real-time monitoring, less …
medical professionals due to its advantages of painlessness, real-time monitoring, less …
Glucose sensing in oral mucosa simulating phantom using differential absorption based frequency domain low-coherence interferometry
The superluminescent diode based differential absorption frequency domain low-coherence
interferometry (FD-DALCI) technique is proposed and demonstrated for sensing …
interferometry (FD-DALCI) technique is proposed and demonstrated for sensing …
[HTML][HTML] Non-Invasive Glucose Measurement Technique Based on Time-of-Flight
K Asimakopoulos, E Hristoforou - Applied Sciences, 2024 - mdpi.com
A novel, low-cost sensor for the measurement of physiological levels of glucose in samples
has been developed using Time-of-Flight (ToF) technology. The sensor, built with off-the …
has been developed using Time-of-Flight (ToF) technology. The sensor, built with off-the …