Review of electron beam therapy physics

KR Hogstrom, PR Almond - Physics in Medicine & Biology, 2006 - iopscience.iop.org
For over 50 years, electron beams have been an important modality for providing an
accurate dose of radiation to superficial cancers and disease and for limiting the dose to …

Design and production of 3D printed bolus for electron radiation therapy

S Su, K Moran, JL Robar - Journal of applied clinical medical …, 2014 - Wiley Online Library
This is a proof‐of‐concept study demonstrating the capacity for modulated electron radiation
therapy (MERT) dose distributions using 3D printed bolus. Previous reports have involved …

The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy

BA Faddegon, I Kawrakow, Y Kubyshin… - Physics in Medicine …, 2009 - iopscience.iop.org
Abstract Three widely used Monte Carlo systems were benchmarked against recently
published measurements of the angular distribution of 13 MeV and 20 MeV electrons …

Tungsten filled 3D printed field shaping devices for electron beam radiation therapy

L Skinner, BP Fahimian, AS Yu - PLoS One, 2019 - journals.plos.org
Purpose Electron radiotherapy is a labor-intensive treatment option that is complicated by
the need for field shaping blocks. These blocks are typically made from casting Cerrobend …

Feasibility of clinical electron beam formation using polymer materials produced by fused deposition modeling

I Miloichikova, A Bulavskaya, Y Cherepennikov… - Physica Medica, 2019 - Elsevier
The main challenge in electron external beam radiation therapy with clinical accelerators is
the absence of integrated systems to form irregular fields. The current approach to provide …

Estimation of out-of-field dose variation using markus ionization chamber detector

AM Abdelaal, EM Attalla, WM Elshemey - SciMedicine Journal, 2020 - scimedjournal.org
Objective: The aim of This work to provide evaluation for the out-of-field dose with different
plan parameters as field size and depth using Markus ionization chamber detector in the …

New radiation therapy techniques for the treatment of head and neck cancer

M Ding, F Newman, D Raben - Otolaryngologic Clinics of North …, 2005 - oto.theclinics.com
Radiation therapy, also referred to as radiotherapy or radiation oncology, is one of the three
principal treatments for cancer, the other two being surgery and chemotherapy. In many …

Characterization of megavoltage electron beams delivered through a photon multi-leaf collimator (pMLC)

FCP Du Plessis, A Leal, S Stathakis… - Physics in Medicine & …, 2006 - iopscience.iop.org
A study is presented that characterizes megavoltage electron beams delivered through an
existing double-focused photon multi-leaf collimator (pMLC) using film measurements in a …

Delivery of modulated electron beams with conventional photon multi-leaf collimators

EE Klein, M Mamalui-Hunter… - Physics in Medicine & …, 2008 - iopscience.iop.org
Electron beam radiotherapy is an accepted method to treat shallow tumors. However,
modulation of electrons to customize dose distributions has not readily been achieved …

Intensity-and energy-modulated electron radiotherapy by means of an xMLC for head and neck shallow tumors

FJ Salguero, R Arráns, BA Palma… - Physics in Medicine & …, 2010 - iopscience.iop.org
The purpose of this paper is to assess the feasibility of delivering intensity-and energy-
modulated electron radiation treatment (MERT) by a photon multileaf collimator (xMLC) and …