Clinical magnetocardiography: The unshielded bet—past, present, and future
Magnetocardiography (MCG), which is nowadays 60 years old, has not yet been fully
accepted as a clinical tool. Nevertheless, a large body of research and several clinical trials …
accepted as a clinical tool. Nevertheless, a large body of research and several clinical trials …
Dual-media laser system: Nitrogen vacancy diamond and red semiconductor laser
Diamond is a potential host material for laser applications due to its exceptional thermal
properties, ultrawide bandgap, and color centers, which promise gain across the visible …
properties, ultrawide bandgap, and color centers, which promise gain across the visible …
Diamond quantum magnetometer with dc sensitivity of sub-10 pT toward measurement of biomagnetic field
N Sekiguchi, M Fushimi, A Yoshimura, C Shinei… - Physical Review …, 2024 - APS
We present a sensitive diamond quantum sensor with a magnetic field sensitivity of 9.4±0.1
pT/Hz in a near-dc frequency range of 5 to 100 Hz. This sensor is based on the continuous …
pT/Hz in a near-dc frequency range of 5 to 100 Hz. This sensor is based on the continuous …
Microscale fiber-integrated vector magnetometer with on-tip field biasing using - ensembles in diamond microcrystals
J Homrighausen, F Hoffmann, J Pogorzelski… - Physical Review …, 2024 - APS
In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond
offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in …
offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in …
Integrated Manipulation and Addressing of Spin Defect in Diamond
MQ Ma, YK Wu, ZW Liu, HX Zang, LK Shan… - Nano Letters, 2024 - ACS Publications
Scalable and addressable integrated manipulation of qubits is crucial for practical quantum
information applications. Different waveguides have been used to transport the optical and …
information applications. Different waveguides have been used to transport the optical and …
Picotesla fiberized diamond-based AC magnetometer
SC Zhang, Y Liu, LK Shan, XD Gao, JQ Geng… - Photonics …, 2024 - opg.optica.org
Portable quantum sensors are crucial for developing practical quantum sensing and
metrology applications. Fiberized nitrogen-vacancy (NV) centers in diamonds have emerged …
metrology applications. Fiberized nitrogen-vacancy (NV) centers in diamonds have emerged …
[HTML][HTML] Exploring the spin dynamics of a room-temperature diamond maser using an extended rate equation model
Y Wen, PL Diggle, NMN Alford, DM Arroo - Journal of Applied Physics, 2023 - pubs.aip.org
Masers—the microwave analog of lasers—are coherent microwave sources that can act as
oscillators or quantum-limited amplifiers. Masers have historically required high vacuum and …
oscillators or quantum-limited amplifiers. Masers have historically required high vacuum and …
A special issue preface: diamond for quantum applications
This special issue discusses current progress in the utilization of defect centres in diamond
as spin–photon interfaces for quantum applications. This issue is based on the discussions …
as spin–photon interfaces for quantum applications. This issue is based on the discussions …
Simultaneous vector magnetometry based on fluorescence polarization of NV centers ensemble in diamond
M Li, H Yuan, P Fan, S Wang, J Shen, L Xu - Applied Physics Letters, 2024 - pubs.aip.org
The nitrogen-vacancy (NV) centers ensemble has extensive application prospects in vector-
magnetic-field measurement due to its accurate and fixed spatial orientations along the …
magnetic-field measurement due to its accurate and fixed spatial orientations along the …
Concurrent sensing of vector magnetic field based on diamond nitrogen-vacancy ensemble using a time-divided hardware-synchronized protocol
Y Zhai, L Cheng, Y Song, J Li, Z Yu, Y Tian… - Review of Scientific …, 2024 - pubs.aip.org
A diamond nitrogen-vacancy (NV) ensemble has been developed as a vector magnetometry
platform for sensing external time-varying magnetic fields. However, due to the complexity of …
platform for sensing external time-varying magnetic fields. However, due to the complexity of …