An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history

XG Xu - Physics in Medicine & Biology, 2014 - iopscience.iop.org
Radiation dose calculation using models of the human anatomy has been a subject of great
interest to radiation protection, medical imaging, and radiotherapy. However, early pioneers …

[PDF][PDF] A review of computational phantoms for quality assurance in radiology and radiotherapy in the deep-learning era

Z Peng, N Gao, B Wu, Z Chen, XG Xu - Journal of Radiation Protection and …, 2022 - jrpr.org
The exciting advancement related to the “modeling of digital human” in terms of a
computational phantom for radiation dose calculations has to do with the latest hype related …

Counting Efficiencies of Shadow Shield Whole Body Counter for Adult and Paediatric Reference Computational Phantoms

R Roy, HK Patni, PK Singh, PD Sawant - Applied Radiation and Isotopes, 2025 - Elsevier
ABSTRACT Shadow Shield Whole Body Counter (SSWBC) is used to estimate internal dose
of radiation workers due to the intake of fission and activation products. The SSWBC …

Estimation of specific absorbed fractions for selected organs due to photons emitted by activity deposited in the human respiratory tract using ICRP/ICRU male voxel …

HK Patni, DK Akar, MY Nadar, VP Ghare… - Radiation protection …, 2013 - academic.oup.com
The ICRP/ICRU adult male reference voxel phantom incorporated in Monte Carlo code
FLUKA is used for estimating specific absorbed fractions (SAFs) for photons due to the …

Comparison of conversion coefficients for equivalent dose in terms of air kerma for photons using a male adult voxel simulator in sitting and standing posture with …

DC Galeano, FR Cavalcante, ABC Júnior… - Radiation Physics and …, 2014 - Elsevier
The dose conversion coefficient (DCC) is important to quantify and assess effective doses
associated with medical, professional and public exposures. The calculation of DCCs using …

Direct Monitoring Method to Detect Internal Radioactive Contamination

MY Nadar, L Mishra, IS Singh - … on Radiation Environment, Volume 2: Dose …, 2024 - Springer
Direct monitoring technique for evaluation of internal contamination is a century old mature
method used for assessment of internal dose. It is used for estimation of organ/whole body …

[HTML][HTML] Estimation of photon specific absorbed fractions in digimouse voxel phantom using Monte Carlo simulation Code FLUKA

A Sinha, HK Patni, BM Dixit, NK Painuly… - Journal of biomedical …, 2016 - ncbi.nlm.nih.gov
Background: Most preclinical studies are carried out on mice. For internal dose assessment
of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies …

Monte Carlo study of the cardiac absorbed dose during X-ray examination of an adult patient

O Kadri, K Manai, A Alfuraih - Radiation Protection Dosimetry, 2016 - academic.oup.com
The computational voxel phantom 'High-Definition Reference Korean-Man (HDRK-Man)'was
implemented into the Monte Carlo transport toolkit Geant4. The voxel model, adjusted to the …

[HTML][HTML] Deterministic and probabilistic analysis of safety in particle accelerators

PK Sarkar - Radiation Protection and Environment, 2012 - journals.lww.com
The complexity involved in accelerator safety is discussed. Starting with the estimation of the
source term the discussion includes design of radiation shield, safety interlock systems. The …

Computational phantoms for organ dose calculations in radiation protection and imaging

X George Xu - The Phantoms of Medical and Health Physics: Devices …, 2013 - Springer
Computational Phantoms for Organ Dose Calculations in Radiation Protection and Imaging |
SpringerLink Skip to main content Advertisement SpringerLink Account Menu Find a journal …