An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history
XG Xu - Physics in Medicine & Biology, 2014 - iopscience.iop.org
Radiation dose calculation using models of the human anatomy has been a subject of great
interest to radiation protection, medical imaging, and radiotherapy. However, early pioneers …
interest to radiation protection, medical imaging, and radiotherapy. However, early pioneers …
[PDF][PDF] A review of computational phantoms for quality assurance in radiology and radiotherapy in the deep-learning era
Z Peng, N Gao, B Wu, Z Chen, XG Xu - Journal of Radiation Protection and …, 2022 - jrpr.org
The exciting advancement related to the “modeling of digital human” in terms of a
computational phantom for radiation dose calculations has to do with the latest hype related …
computational phantom for radiation dose calculations has to do with the latest hype related …
Counting Efficiencies of Shadow Shield Whole Body Counter for Adult and Paediatric Reference Computational Phantoms
ABSTRACT Shadow Shield Whole Body Counter (SSWBC) is used to estimate internal dose
of radiation workers due to the intake of fission and activation products. The SSWBC …
of radiation workers due to the intake of fission and activation products. The SSWBC …
Estimation of specific absorbed fractions for selected organs due to photons emitted by activity deposited in the human respiratory tract using ICRP/ICRU male voxel …
The ICRP/ICRU adult male reference voxel phantom incorporated in Monte Carlo code
FLUKA is used for estimating specific absorbed fractions (SAFs) for photons due to the …
FLUKA is used for estimating specific absorbed fractions (SAFs) for photons due to the …
Comparison of conversion coefficients for equivalent dose in terms of air kerma for photons using a male adult voxel simulator in sitting and standing posture with …
DC Galeano, FR Cavalcante, ABC Júnior… - Radiation Physics and …, 2014 - Elsevier
The dose conversion coefficient (DCC) is important to quantify and assess effective doses
associated with medical, professional and public exposures. The calculation of DCCs using …
associated with medical, professional and public exposures. The calculation of DCCs using …
Direct Monitoring Method to Detect Internal Radioactive Contamination
Direct monitoring technique for evaluation of internal contamination is a century old mature
method used for assessment of internal dose. It is used for estimation of organ/whole body …
method used for assessment of internal dose. It is used for estimation of organ/whole body …
[HTML][HTML] Estimation of photon specific absorbed fractions in digimouse voxel phantom using Monte Carlo simulation Code FLUKA
Background: Most preclinical studies are carried out on mice. For internal dose assessment
of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies …
of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies …
Monte Carlo study of the cardiac absorbed dose during X-ray examination of an adult patient
The computational voxel phantom 'High-Definition Reference Korean-Man (HDRK-Man)'was
implemented into the Monte Carlo transport toolkit Geant4. The voxel model, adjusted to the …
implemented into the Monte Carlo transport toolkit Geant4. The voxel model, adjusted to the …
[HTML][HTML] Deterministic and probabilistic analysis of safety in particle accelerators
PK Sarkar - Radiation Protection and Environment, 2012 - journals.lww.com
The complexity involved in accelerator safety is discussed. Starting with the estimation of the
source term the discussion includes design of radiation shield, safety interlock systems. The …
source term the discussion includes design of radiation shield, safety interlock systems. The …
Computational phantoms for organ dose calculations in radiation protection and imaging
X George Xu - The Phantoms of Medical and Health Physics: Devices …, 2013 - Springer
Computational Phantoms for Organ Dose Calculations in Radiation Protection and Imaging |
SpringerLink Skip to main content Advertisement SpringerLink Account Menu Find a journal …
SpringerLink Skip to main content Advertisement SpringerLink Account Menu Find a journal …