[HTML][HTML] Use of Patient-Specific Instrumentation (PSI) for glenoid component positioning in shoulder arthroplasty. A systematic review and meta-analysis

G Villatte, AS Muller, B Pereira, A Mulliez, P Reilly… - PloS one, 2018 - journals.plos.org
Introduction Total Shoulder Arthroplasty (TSA) anatomical, reverse or both is an increasingly
popular procedure but the glenoid component is still a weak element, accounting for 30 …

Addressing glenoid bone deficiency and asymmetric posterior erosion in shoulder arthroplasty

JE Hsu, ET Ricchetti, GR Huffman, JP Iannotti… - Journal of Shoulder and …, 2013 - Elsevier
Glenoid bone deficiency and eccentric posterior wear are difficult problems faced by
shoulder arthroplasty surgeons. Numerous options and techniques exist for addressing …

Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study

G Walch, PS Vezeridis, P Boileau, P Deransart… - Journal of Shoulder and …, 2015 - Elsevier
Background Glenoid component positioning is a key factor for success in total shoulder
arthroplasty. Three-dimensional (3D) measurements of glenoid retroversion, inclination, and …

Comparison of patient-specific instruments with standard surgical instruments in determining glenoid component position: a randomized prospective clinical trial

MD Hendel, JA Bryan, WK Barsoum, EJ Rodriguez… - JBJS, 2012 - journals.lww.com
Background: Glenoid component malposition for anatomic shoulder replacement may result
in complications. The purpose of this study was to define the efficacy of a new surgical …

Automated three-dimensional measurement of glenoid version and inclination in arthritic shoulders

P Boileau, D Cheval, MO Gauci, N Holzer, J Chaoui… - JBJS, 2018 - journals.lww.com
Background: Preoperative computed tomography (CT) measurements of glenoid version
and inclination are recommended for planning glenoid implantation in shoulder arthroplasty …

Patient-specific glenoid guides provide accuracy and reproducibility in total shoulder arthroplasty

MO Gauci, P Boileau, M Baba, J Chaoui… - The bone & joint …, 2016 - boneandjoint.org.uk
Aims Patient-specific glenoid guides (PSGs) claim an improvement in accuracy and
reproducibility of the positioning of components in total shoulder arthroplasty (TSA). The …

Patient-specific targeting guides compared with traditional instrumentation for glenoid component placement in shoulder arthroplasty: a multi-surgeon study in 70 …

TW Throckmorton, LV Gulotta, FO Bonnarens… - Journal of shoulder and …, 2015 - Elsevier
Hypothesis and background The purpose of this study was to compare the accuracy of
patient-specific guides for total shoulder arthroplasty (TSA) with traditional instrumentation in …

Effect of glenoid deformity on glenoid component placement in primary shoulder arthroplasty

JP Iannotti, C Greeson, D Downing, V Sabesan… - Journal of shoulder and …, 2012 - Elsevier
BACKGROUND: Malposition of the glenoid component can result in premature component
loosening or instability. This study was designed to test the ability of an experienced …

Accuracy of 3-dimensional planning, implant templating, and patient-specific instrumentation in anatomic total shoulder arthroplasty

JP Iannotti, K Walker, E Rodriguez, TE Patterson… - JBJS, 2019 - journals.lww.com
Background: Use of 3-dimensional (3D) computed tomography (CT) preoperative planning
and patient-specific instrumentation has been demonstrated to improve the accuracy of …

Progression of glenoid morphology in glenohumeral osteoarthritis

KE Walker, XC Simcock, BJ Jun, JP Iannotti… - JBJS, 2018 - journals.lww.com
Background: Walch defined the pathologic characteristics of glenohumeral osteoarthritis on
the basis of patterns of glenoid morphology and humeral head subluxation. However, it is …