A review of the performance of different ventilation and airflow distribution systems in buildings
The objective of this article is to review the scientific literature on airflow distribution systems
and ventilation effectiveness to identify and assess the most suitable room air distribution …
and ventilation effectiveness to identify and assess the most suitable room air distribution …
Experimental and numerical analysis of the autoignition behavior of NH3 and NH3/H2 mixtures at high pressure
L Dai, S Gersen, P Glarborg, H Levinsky… - Combustion and flame, 2020 - Elsevier
Measurements of autoignition delay times of NH 3 and NH 3/H 2 mixtures in a rapid
compression machine are reported at pressures from 20–75 bar and temperatures in the …
compression machine are reported at pressures from 20–75 bar and temperatures in the …
Advanced air distribution: improving health and comfort while reducing energy use
AK Melikov - Indoor air, 2016 - Wiley Online Library
Indoor environment affects the health, comfort, and performance of building occupants. The
energy used for heating, cooling, ventilating, and air conditioning of buildings is substantial …
energy used for heating, cooling, ventilating, and air conditioning of buildings is substantial …
Investigation on indoor airflow and contaminant dispersion of diffuse ceiling ventilation in heating and cooling modes
P Peng, C Zhang, W Li, M Pomianowski, G Gong… - Journal of Building …, 2023 - Elsevier
This paper systematically investigates the indoor airflow and contaminant dispersion of
diffuse ceiling ventilation (DCV) for space heating and cooling. A numerical model of the …
diffuse ceiling ventilation (DCV) for space heating and cooling. A numerical model of the …
Ventilation for good indoor air quality and energy efficiency
HB Awbi - Energy Procedia, 2017 - Elsevier
As a result of new energy efficiency directives and legislations in Europe and elsewhere, the
ventilation component of energy usage in buildings has increased relative to the total energy …
ventilation component of energy usage in buildings has increased relative to the total energy …
Thermal environment and air quality in office with personalized ventilation combined with chilled ceiling
A Lipczynska, J Kaczmarczyk, AK Melikov - Building and Environment, 2015 - Elsevier
The thermal environment and air quality conditions provided with combined system of
chilled ceiling and personalized ventilation (PV) were studied in a simulated office room for …
chilled ceiling and personalized ventilation (PV) were studied in a simulated office room for …
[HTML][HTML] Bedroom ventilation performance in daycare centers under three typical ventilation strategies
With increasing reliance on daycare centers for early childhood development, ensuring
healthy environments in semi-enclosed baby beds for napping is crucial, given infants' …
healthy environments in semi-enclosed baby beds for napping is crucial, given infants' …
Heating energy consumption of impinging jet ventilation and mixing ventilation in large-height spaces: A comparison study
X Ye, H Zhu, Y Kang, K Zhong - Energy and Buildings, 2016 - Elsevier
Heating energy consumptions are compared when impinging jet ventilation (IJV) and mixing
ventilation (MV) systems are used in heating modes in large-height spaces. The indoor …
ventilation (MV) systems are used in heating modes in large-height spaces. The indoor …
Experimental study on air change effectiveness in mixing ventilation
H Amai, A Novoselac - Building and Environment, 2016 - Elsevier
Mixing ventilation is the most common air distribution system, and often the same diffusers
provide space cooling and heating. Proper diffuser selection affects characteristics of air …
provide space cooling and heating. Proper diffuser selection affects characteristics of air …
Thermal environment in simulated offices with convective and radiant cooling systems under cooling (summer) mode of operation
P Mustakallio, Z Bolashikov, K Kostov, A Melikov… - Building and …, 2016 - Elsevier
The thermal environment in a double office room and in a six-person meeting room obtained
with chilled beam (CB), chilled beam with radiant panel (CBR), chilled ceiling with ceiling …
with chilled beam (CB), chilled beam with radiant panel (CBR), chilled ceiling with ceiling …