Diagnosis of cracked teeth using cone-beam computed tomography: literature review and clinical experience

A Gao, D Cao, Z Lin - Dentomaxillofacial Radiology, 2021 - academic.oup.com
Cone-beam computed tomography (CBCT) has been widely used in diagnosis of vertical
root fractures (VRFs) in recent years. According to the American Association of Endodontists …

Influence of the technical parameters of CBCT image acquisition on vertical root fracture diagnosis: a systematic review and meta-analysis

KL de Lima, LR Silva, TB de Paiva Prado… - Clinical Oral …, 2023 - Springer
Objectives To evaluate the influence of image acquisition parameters (voxel, FOV, kVp, mA)
on the accuracy of cone-beam computed tomography (CBCT) in detecting vertical root …

Optimization of tube current in cone-beam computed tomography for the detection of vertical root fractures with different intracanal materials

H Gaêta-Araujo, GQS de Souza, DQ Freitas… - Journal of …, 2017 - Elsevier
Introduction There is no consensus about the accuracy of cone-beam computed tomography
(CBCT) for detecting vertical root fractures (VRFs), nor is there certainty about the isolated …

Effect of anatomical region on the formation of metal artefacts produced by dental implants in cone beam computed tomographic images

AH Machado, KAC Fardim, CF de Souza… - Dentomaxillofacial …, 2018 - academic.oup.com
Objectives: To quantitatively compare metal artefacts produced by implants in different
maxillomandibular regions on cone beam CT (CBCT) images. Methods: A total of 200 …

[HTML][HTML] The efficacy of metal artifact reduction mode in cone-beam computed tomography images on diagnostic accuracy of root fractures in teeth with intracanal …

ZD Kajan, M Taramsari, NK Fard… - Iranian endodontic …, 2018 - ncbi.nlm.nih.gov
Results: The percentage of correct diagnosis using the WMAR mode in both the post space
and pin groups in the presence of root fracture was 46.6%; with MAR, it increased to 86.6 …

Minimal detectable width of tooth fractures using magnetic resonance imaging and method to measure

BR Groenke, D Idiyatullin, L Gaalaas, A Petersen… - Journal of …, 2022 - Elsevier
Introduction Vertical root fracture (VRF) in root canal–treated (RCT) teeth is a common cause
of pain, bone resorption, and tooth loss. VRF is also difficult to diagnose and measure …

[PDF][PDF] Diagnostic accuracy of conventional, digital and Cone Beam CT in vertical root fracture detection

S Valizadeh, M Khosravi, Z Azizi - 2011 - sid.ir
Abstract INTRODUCTION: VERTICAL ROOT FRACTURE (VRF) is a common failure in
endodontically treated teeth. Due to VRF's poor prognosis, a reliable and valid detection …

Vertical root fracture: Biological effects and accuracy of diagnostic imaging methods

TM Baageel, EH Allah, GT Bakalka… - … Society of Preventive …, 2016 - journals.lww.com
This review assessed the most up-to-date literature on the accuracy of detecting vertical root
fractures (VRFs] using the currently available diagnostic imaging methods. In addition, an …

[HTML][HTML] Cone-beam computed tomography artifacts in the presence of dental implants and associated factors: an integrative review

BR Terrabuio, CG Carvalho… - Imaging science in …, 2021 - ncbi.nlm.nih.gov
Purpose This study was conducted to review the literature regarding the types of cone-beam
computed tomography (CBCT) artifacts around dental implants and the factors that influence …

Expression of artefacts from different orthodontic brackets and wires in cone beam computed tomography scans-an in vitro study

BS Troca, HMA Felizardo, H Gaêta-Araujo - Clinical Oral Investigations, 2024 - Springer
Objectives To investigate artefacts produced by different orthodontic brackets and wires in
cone-beam computed tomography (CBCT) scans. Materials and methods Two dental arches …