[HTML][HTML] Automated EEG source imaging: a retrospective, blinded clinical validation study

AG Baroumand, P van Mierlo, G Strobbe… - Clinical …, 2018 - Elsevier
Objective To evaluate the accuracy of automated EEG source imaging (ESI) in localizing
epileptogenic zone. Methods Long-term EEG, recorded with the standard 25-electrode array …

[HTML][HTML] EEG source connectivity to localize the seizure onset zone in patients with drug resistant epilepsy

W Staljanssens, G Strobbe, R Van Holen… - NeuroImage: Clinical, 2017 - Elsevier
Electrical source imaging (ESI) from interictal scalp EEG is increasingly validated and used
as a valuable tool in the presurgical evaluation of epilepsy as a reflection of the irritative …

Automated long‐term EEG analysis to localize the epileptogenic zone

P van Mierlo, G Strobbe, V Keereman, G Birot… - Epilepsia …, 2017 - Wiley Online Library
Objective We investigated the performance of automatic spike detection and subsequent
electroencephalogram (EEG) source imaging to localize the epileptogenic zone (EZ) from …

Automated ictal EEG source imaging: A retrospective, blinded clinical validation study

AG Baroumand, AA Arbune, G Strobbe… - Clinical …, 2022 - Elsevier
Objective EEG source imaging (ESI) is a validated tool in the multimodal workup of patients
with drug resistant focal epilepsy. However, it requires special expertise and it is …

[HTML][HTML] Automated interictal source localisation based on high-density EEG

BJ Vorderwülbecke, AG Baroumand, L Spinelli… - Seizure, 2021 - Elsevier
Purpose To study the accuracy of automated interictal EEG source localisation based on
high-density EEG, and to compare it to low-density EEG. Methods Thirty patients operated …

[HTML][HTML] Ictal EEG source imaging and connectivity to localize the seizure onset zone in extratemporal lobe epilepsy

S Vespa, AG Baroumand, SF Santos, P Vrielynck… - Seizure, 2020 - Elsevier
Purpose To evaluate the yield of Functional Connectivity (FC) in addition to low-density ictal
Electrical Source Imaging (ESI) in extratemporal lobe epilepsy (ETLE), using an automated …

Influence of Patient‐Specific Head Modeling on EEG Source Imaging

Y Céspedes-Villar, JD Martinez-Vargas… - … Methods in Medicine, 2020 - Wiley Online Library
Electromagnetic source imaging (ESI) techniques have become one of the most common
alternatives for understanding cognitive processes in the human brain and for guiding …

[HTML][HTML] Numerical Investigation of Layered Homogeneous Skull Model for Simulations of Transcranial Focused Ultrasound

H Seo, M Han, J Choi, S Kim, J Park, EH Lee - … : Technology at the Neural …, 2024 - Elsevier
Abstract Background and Objectives The influence of the intracranial pressure field must be
discussed with the development of a single-element transducer for low-intensity transcranial …

[PDF][PDF] Evaluation and Comparison of the Value of Source Localization on the Basis of MEG and High-density EEG within the Presurgical Evaluation of Patients with …

D Croes - libstore.ugent.be
Evaluation and Comparison of the Value of Source Localization on the Basis of MEG and
High-density EEG within the Presurgical Ev Page 1 Evaluation and Comparison of the …

Three‐dimensional FDTD modeling of neurons to solve EEG and MEG forward problem

S Hashemi, A Abdolali - International Journal of Imaging …, 2017 - Wiley Online Library
Neuronal activities including calcium sodium current, ligands current, and synaptic
transmembrane current create electromagnetic fields. Here, an analytic method is suggested …