A d-axis based current differential protection scheme for an active distribution network
L Zang, G Zou, C Zhou, M Zheng, T Du - Protection and Control of Modern …, 2022 - Springer
The emergence of distributed generators has changed the operational mode and fault
characteristics of the distribution network, in a way which can severely influence protection …
characteristics of the distribution network, in a way which can severely influence protection …
Superimposed current based differential protection scheme for AC microgrid feeders
Legacy protection schemes face numerous challenges with the emergence of microgrids.
Due to the complex controls, the fault responses in microgrids differ from conventional …
Due to the complex controls, the fault responses in microgrids differ from conventional …
A Lissajous Curve–Based Method for Busbar Protection
M Sarlak - International Transactions on Electrical Energy …, 2024 - Wiley Online Library
In this paper, a novel time‐domain method based on the orientation analysis of the
superimposed current component Lissajous curves is presented for busbar protection. The …
superimposed current component Lissajous curves is presented for busbar protection. The …
Review of Bus Differential Protection Using IEC 61850
The electrical power system is susceptible to several faults, which can cause the system to
malfunction. Among these, the ones that occur in the busbars of substations stand out. The …
malfunction. Among these, the ones that occur in the busbars of substations stand out. The …
Busbar differential protection using an alternative generalized alpha plane
FAM Vásquez, KM Silva - Electric Power Systems Research, 2021 - Elsevier
This paper describes an alternative busbar differential protection function based on the
generalized alpha plane. This approach faithfully maps several currents in two equivalent …
generalized alpha plane. This approach faithfully maps several currents in two equivalent …
A new time domain-based busbar protection algorithm
FAM Vásquez, EP Ribeiro, KM Silva… - Electric Power Systems …, 2021 - Elsevier
This paper presents a new time domain busbar protection algorithm which uses current
samples and their half-cycle incremental quantities to implement a fast and reliable tripping …
samples and their half-cycle incremental quantities to implement a fast and reliable tripping …
Busbar Protection Algorithm Improvement Based on Combination of dq0 Transform and Wavelet Transform
MSB Pirnat - Russian Electrical Engineering, 2022 - Springer
In this work we have studied the possible use of dq 0 transformation in combination with
discrete wavelet transform (DWT) to implement a fast and selective busbar differential …
discrete wavelet transform (DWT) to implement a fast and selective busbar differential …