Implications on clinical scenario of gold nanoparticle radiosensitization in regards to photon energy, nanoparticle size, concentration and location

E Lechtman, N Chattopadhyay, Z Cai… - Physics in Medicine …, 2011 - iopscience.iop.org
Gold nanoparticle (AuNP) radiosensitization represents a novel approach to enhance the
effectiveness of ionizing radiation. Its efficiency varies widely with photon source energy and …

An EGSnrc Monte Carlo‐calculated database of TG‐43 parameters

REP Taylor, DWO Rogers - Medical physics, 2008 - Wiley Online Library
Monte Carlo methods are used to calculate a complete TG‐43 dosimetry parameter data set
for 27 low‐energy photon emitting brachytherapy sources (18 and 9). All Monte Carlo …

Supplement 2 for the 2004 update of the AAPM Task Group No. 43 Report: joint recommendations by the AAPM and GEC‐ESTRO

MJ Rivard, F Ballester, WM Butler, LA DeWerd… - Medical …, 2017 - Wiley Online Library
Since the publication of the 2004 update to the American Association of Physicists in
Medicine (AAPM) Task Group No. 43 Report (TG‐43U1) and its 2007 supplement (TG …

Validation of the TOPAS Monte Carlo toolkit for LDR brachytherapy simulations

A Poher, F Berumen, Y Ma, J Perl, L Beaulieu - Physica Medica, 2023 - Elsevier
Purpose: This work has the purpose of validating the Monte Carlo toolkit TOol for PArticle
Simulation (TOPAS) for low-dose-rate (LDR) brachytherapy uses. Methods and Materials …

[HTML][HTML] Application of Monte Carlo calculations for validation of a treatment planning system in high dose rate brachytherapy

A Naseri, A Mesbahi - Reports of Practical Oncology & Radiotherapy, 2009 - Elsevier
AIM: The accuracy of treatment planning systems is of vital importance in treatment
outcomes in brachytherapy. In the current study the accuracy of dose calculations of a high …

Collision-kerma conversion between dose-to-tissue and dose-to-water by photon energy-fluence corrections in low-energy brachytherapy

V Giménez-Alventosa, PCG Antunes… - Physics in Medicine …, 2016 - iopscience.iop.org
The AAPM TG-43 brachytherapy dosimetry formalism, introduced in 1995, has become a
standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle …

Evaluation of water-mimicking solid phantom materials for use in HDR and LDR brachytherapy dosimetry

AA Schoenfeld, M Thieben, D Harder… - Physics in Medicine …, 2017 - iopscience.iop.org
In modern HDR or LDR brachytherapy with photon emitters, fast checks of the dose profiles
generated in water or a water-equivalent phantom have to be available in the interest of …

Photon activation therapy: a Monte Carlo study on dose enhancement by various sources and activation media

M Bakhshabadi, M Ghorbani, AS Meigooni - Australasian physical & …, 2013 - Springer
In the present study, a number of brachytherapy sources and activation media were
simulated using MCNPX code and the results were analyzed based on the dose …

Determination of dosimetry parameters of ADVANTAGETM 103Pd brachytherapy seed using MCNP4C computer code

V Ataeinia, G Raisali, M Sadeghi - Nukleonika, 2009 - yadda.icm.edu.pl
The IsoAid LLC Inc. has been introduced ADVANTAGETM 103Pd brachytherapy seed in
2006. The aim of this work is to determine the dosimetric characteristics of this seed …

[HTML][HTML] Evaluation of hypothetical 153Gd source for use in brachytherapy

M Ghorbani, M Behmadi - Reports of Practical Oncology & Radiotherapy, 2016 - Elsevier
Aim The purpose of this work is to evaluate the dosimetric parameters of a hypothetical 153
Gd source for use in brachytherapy and comparison of the dosimetric parameters with those …