Towards automated inspections of tunnels: A review of optical inspections and autonomous assessment of concrete tunnel linings

A Sjölander, V Belloni, A Ansell, E Nordström - Sensors, 2023 - mdpi.com
In recent decades, many cities have become densely populated due to increased
urbanization, and the transportation infrastructure system has been heavily used. The …

An experimental assessment of corrosion damage and bending capacity reduction of singly reinforced concrete beams subjected to accelerated corrosion

H Nasser, C Van Steen, L Vandewalle… - … and Building Materials, 2021 - Elsevier
Many existing concrete structures damaged by corrosion show signs of deterioration. The
assessment of the structural performance of their components requires understanding the …

Machine learning-based flexural capacity prediction of corroded RC beams with an efficient and user-friendly tool

A Abushanab, TG Wakjira, W Alnahhal - Sustainability, 2023 - mdpi.com
Steel corrosion poses a serious threat to the structural performance of reinforced concrete
(RC) structures. Thus, this study evaluates the flexural capacity of RC beams through …

Chloride-induced corrosion in reinforced concrete and fiber reinforced concrete elements under tensile service loads

B Leporace-Guimil, A Conforti, R Zerbino… - Cement and Concrete …, 2021 - Elsevier
Corrosion of rebars is one of the main issues affecting the service life of Reinforced
Concrete (RC) structures. It is well-known that the use of fibers enhances the mechanical …

Effect of pre-existing longitudinal and transverse corrosion cracks on the flexural behaviour of corroded RC beams

H Nasser, L Vandewalle, E Verstrynge - Construction and Building …, 2022 - Elsevier
Assessing the residual capacity of corroded reinforced concrete (RC) beams depends on
quantifying the corrosion cracks and rebar cross-section loss, and understanding their …

Physical, mechanical and durability properties of GFRP bars with modified acrylic resin (modar) matrix

S Spagnuolo, Z Rinaldi, J Donnini, A Nanni - Composite Structures, 2021 - Elsevier
Glass fiber reinforced polymer (GFRP) bars are currently used as internal reinforcement of
concrete structures, as an alternative to traditional steel rebars, to avoid corrosion problems …

Experimental research on the degradation law of the bond performance between steel bars and concrete with rust expansion cracking

T Liu, Z Xu, T Huang, J Yang, Y Huang, N Xu… - … and Building Materials, 2024 - Elsevier
Abstracts Chloride ion attack leads to the corrosion of steel bars, causing cracking of the
concrete protective layer and affecting the bonding performance between steel bars and …

Experimental study on the cyclic bond behavior of corroded rebar based on modified beam test

X Zhang, Y Zhao, Z Zhu, S Sha, C Lv - Journal of Building Engineering, 2022 - Elsevier
The corrosion of rebar results in the degradation of bond between rebar and concrete, thus
is unfavorable to the safety of reinforced concrete structures. So far, many studies were …

3D mesoscale simulation of the influence of corrosion on loss of tension stiffening in reinforced concrete

K Avadh, P Jiradilok, JE Bolander, K Nagai - Construction and Building …, 2022 - Elsevier
Corrosion-induced bond degradation leads to changes in deformation characteristics,
cracking patterns, and loss in tension stiffening in structural members. Since the induced …

Corrosion level estimation by means of the surface crack width

A Benenato, B Ferracuti, S Imperatore… - Construction and Building …, 2022 - Elsevier
Since the concrete cover cracking is the earliest visible manifestation of corrosion, a
relationship between crack opening and corrosion level can be a useful non-destructive tool …