Blackbody-sensitive room-temperature infrared photodetectors based on low-dimensional tellurium grown by chemical vapor deposition
Blackbody-sensitive room-temperature infrared detection is a notable development direction
for future low-dimensional infrared photodetectors. However, because of the limitations of …
for future low-dimensional infrared photodetectors. However, because of the limitations of …
[HTML][HTML] Achieving high-resolution thermal imagery in low-contrast lake surface waters by aerial remote sensing and image registration
A two-platform measurement system for realizing airborne thermography of the Lake Surface
Water Temperature (LSWT) with~ 0.8 m pixel resolution (sub-pixel satellite scale) is …
Water Temperature (LSWT) with~ 0.8 m pixel resolution (sub-pixel satellite scale) is …
Characterization of MWIR quantum well infrared photodetectors imaging sensor arrays on InP substrates
O Tanış - 2023 - open.metu.edu.tr
QWIP (Quantum Well Infrared Photodetector) technology has been researched for over 30
years to create a strong alternative to low bandgap material-based IR (Infrared) …
years to create a strong alternative to low bandgap material-based IR (Infrared) …
Study on the thermal imaging application of quantum cascade detectors
SQ Zhai, JQ Liu, XJ Wang, S Tan, FQ Liu… - Infrared Physics & …, 2014 - Elsevier
A 2D mechanical scanning setup was constructed, and was used to evaluate the potential of
quantum cascade detector (QCD) for IR imaging. The peak responsivity of the studied QCD …
quantum cascade detector (QCD) for IR imaging. The peak responsivity of the studied QCD …
Features for instantaneous emissions of low-level infrared signals of glucokinase enzyme from pyrococcus furiosus
A noncontact infrared (IR) imaging-based methodology and signal recovery tools are
applied on an enzyme reaction as a test target. The method is implemented by a long-wave …
applied on an enzyme reaction as a test target. The method is implemented by a long-wave …
Non-contact measurement technique for enzymatic reaction of glucokinase
A non-contact infrared imaging-based measurement technique is applied to quantify the
enzymatic reaction of glucokinase. The method is implemented by a long-wave (8-12 [μm]) …
enzymatic reaction of glucokinase. The method is implemented by a long-wave (8-12 [μm]) …
An experimental validation of the Gauss-Markov model for nonuniformity noise in infrared focal plane array sensors
O Zapata, F Pedreros, SN Torres - Infrared Imaging Systems …, 2012 - spiedigitallibrary.org
The aim of this research is to experimentally validate a Gauss-Markov model, previously
developed by our group, for the non-uniformity parameters of infrared (IR) focal plane arrays …
developed by our group, for the non-uniformity parameters of infrared (IR) focal plane arrays …