Flow-induced vibration of a circular cylinder with splitter plates placed upstream and downstream individually and simultaneously
Flow-induced vibration (FIV) of a circular cylinder with splitter plates placed upstream and
downstream individually and simultaneously at a low Reynolds number of 120 is …
downstream individually and simultaneously at a low Reynolds number of 120 is …
Simultaneous CFD evaluation of VIV suppression using smaller control cylinders
H Zhu, J Yao, Y Ma, H Zhao, Y Tang - Journal of Fluids and Structures, 2015 - Elsevier
Two-degree-of-freedom vortex-induced vibrations (VIV) of a circular cylinder with and
without two smaller control cylinders are investigated numerically by computational fluid …
without two smaller control cylinders are investigated numerically by computational fluid …
Effect of splitter plate length on FIV of circular cylinder
The influence of the plate length on the flow-induced vibration (FIV) of a circular cylinder with
a rigid splitter plate is numerically studied at a low Reynolds number of 100. The mass and …
a rigid splitter plate is numerically studied at a low Reynolds number of 100. The mass and …
The role of wake splitter deflector on performance enhancement of Savonius wind turbine
The Savonius drag-type wind turbine suffers from poor efficiency due to the adverse
negative torques on the returning blades when they rotate against incoming flows. It was …
negative torques on the returning blades when they rotate against incoming flows. It was …
The passive control of wake flow behind a circular cylinder by parallel dual plates
Y Bao, J Tao - Journal of Fluids and Structures, 2013 - Elsevier
In this paper, the wake control of a circular cylinder by dual plates symmetrically attached at
the rear surface is numerically investigated within the laminar flow regime. The two flat …
the rear surface is numerically investigated within the laminar flow regime. The two flat …
Performance enhancement for tube bank staggered configuration heat exchanger–CFD Study
AMN Elmekawy, AA Ibrahim, AM Shahin, S Al-Ali… - … and Processing-Process …, 2021 - Elsevier
The effect of attaching a splitter plate to the circular tube on the performance of a heat
exchanger with a circular tube bank is investigated. A CFD model is developed to simulate …
exchanger with a circular tube bank is investigated. A CFD model is developed to simulate …
POD analysis of the wake behind a circular cylinder with splitter plate
D Deep, A Sahasranaman, S Senthilkumar - European Journal of …, 2022 - Elsevier
Flow past a circular cylinder is a widely studied phenomenon which finds application in a
wide array of real life scenarios, like flow past cables, poles, building protrusions …
wide array of real life scenarios, like flow past cables, poles, building protrusions …
CFD analysis of flow-induced rotation of a circular cylinder with a detached rear splitter plate in laminar flow
This paper numerically investigated the flow-induced rotation response of an elastically
mounted circular cylinder fitted with a detached rear splitter plate in laminar flow. With the …
mounted circular cylinder fitted with a detached rear splitter plate in laminar flow. With the …
Characteristics and suppression of flow-induced vibrations of two side-by-side circular cylinders
S Kim, MM Alam - Journal of Fluids and Structures, 2015 - Elsevier
A free-vibration experiment was conducted to examine flow-induced vibration (FIV)
characteristics of two identical circular cylinders in side-by-side arrangements at spacing …
characteristics of two identical circular cylinders in side-by-side arrangements at spacing …
Experimental and CFD prediction of heat transfer and friction factor characteristics in cross flow tube bank with integral splitter plate
The experimental and the three-dimensional numerical simulation of cross flow tube bank in
staggered arrangements with and without the splitter plate attachment is performed with …