RC walls in Australia: Seismic design and detailing to AS 1170.4 and AS 3600
SJ Menegon, JL Wilson, NTK Lam… - Australian Journal of …, 2018 - Taylor & Francis
This paper reviews the current seismic design procedures for reinforced concrete buildings
in Australia, with direct reference to the Australian earthquake loading code, AS 1170.4 and …
in Australia, with direct reference to the Australian earthquake loading code, AS 1170.4 and …
Response of thin lightly-reinforced concrete walls under cyclic loading
During the last two decades, thin concrete walls have been frequently used to brace mid-to
high-rise buildings in some Latin American countries. This structural system differs …
high-rise buildings in some Latin American countries. This structural system differs …
In-plane cyclic testing of precast concrete wall panels with grouted metal duct base connections
In order to achieve satisfactory seismic performance the connections between precast
concrete wall panels and other structural elements should be well-designed to avoid brittle …
concrete wall panels and other structural elements should be well-designed to avoid brittle …
Machine learning based prediction model for plastic hinge length calculation of reinforced concrete structural walls
MS Barkhordari, A Jawdhari - Advances in Structural …, 2023 - journals.sagepub.com
Reinforced concrete structural walls (RCSWs) are integral part of buildings and other
structures and are used to carry in-plane and out-plane loads. For assessment purposes …
structures and are used to carry in-plane and out-plane loads. For assessment purposes …
[HTML][HTML] Response of RC shear walls with single and double layers of reinforcements subjected to in-plane cyclic loading
Reinforced concrete (RC) shear walls are primarily designed to resist lateral actions in
buildings, in addition to carrying the vertical loads from above. Recent changes in the …
buildings, in addition to carrying the vertical loads from above. Recent changes in the …
Bar buckling in ductile RC walls with different boundary zone detailing: Experimental investigation
The performance of reinforced concrete (RC) structural walls during the past earthquakes in
New Zealand (2010–11) and Chile (2010) have highlighted the susceptibility of these critical …
New Zealand (2010–11) and Chile (2010) have highlighted the susceptibility of these critical …
Seismic performance of a new type of precast shear walls with non-connected vertical distributed reinforcement
X Liao, S Zhang, Z Cao, X Xiao - Journal of Building Engineering, 2021 - Elsevier
To eliminate the shortcomings in the grouting sleeve and other connection forms in precast
concrete shear wall structure induced by the poor grouting, difficult quality assurance, low …
concrete shear wall structure induced by the poor grouting, difficult quality assurance, low …
Impact of axial load on the seismic response of rectangular walls
Experimental testing was conducted on four large-scale, flexure-yielding walls with
rectangular cross sections to investigate the impact of imposed axial load ratio (10, 14, and …
rectangular cross sections to investigate the impact of imposed axial load ratio (10, 14, and …
Tests on slender ductile structural walls designed according to New Zealand Standard
This paper presents an experimental study conducted to investigate the seismic
performance and out-of-plane response of three rectangular doubly reinforced ductile wall …
performance and out-of-plane response of three rectangular doubly reinforced ductile wall …
Numerical modelling of reinforced concrete walls with minimum vertical reinforcement
Recent experimental results have shown that current minimum vertical reinforcement limits
in many concrete design standards are insufficient to ensure that large ductility can be …
in many concrete design standards are insufficient to ensure that large ductility can be …