The radiological assessment of total and unicompartmental knee replacements

SS Sarmah, S Patel, FS Hossain… - The Journal of Bone & …, 2012 - boneandjoint.org.uk
Radiological assessment of total and unicompartmental knee replacement remains an
essential part of routine care and follow-up. Appreciation of the various measurements that …

Volumetric wear assessment of retrieved metal-on-metal hip prostheses and the impact of measurement uncertainty

PJ Bills, R Racasan, RJ Underwood, P Cann, J Skinner… - Wear, 2012 - Elsevier
In hip replacement the use of hard bearing materials, which have been shown to have lower
wear rates than traditional metal-UHMWPE couples, has been encouraged in an effort to …

Long-term wear of dual mobility total hip replacement cups: explant study

B Boyer, T Neri, J Geringer, A Di Iorio… - International …, 2018 - Springer
Purpose Dual mobility THA implantations are increasing. THA survival of more than 15 years
is considered long-term survival based on the Charnley prosthesis, which has a median …

The in vivo linear and volumetric wear of hip resurfacing implants revised for pseudotumor

S Glyn-Jones, A Roques, A Taylor, YM Kwon… - JBJS, 2011 - journals.lww.com
Background: Metal-on-metal arthroplasty-related pseudotumors can cause severe local
destruction of bone and soft tissues. The cause of pseudotumors is unknown, although some …

The influence of implant design and limb alignment on in vivo wear rates of fixed‐bearing and rotating‐platform knee implant retrievals

MJ Dreyer, B Weisse… - Journal of …, 2024 - Wiley Online Library
Abstract Analysis of polyethylene (PE) wear in knee implants is crucial for understanding the
factors leading to revision in total knee arthroplasty. Importantly, current experimental and …

Knee wear assessment: 3D scanners used as a consolidated procedure

S Affatato, MC Valigi, S Logozzo - Materials, 2020 - mdpi.com
It is well known that wear occurring in polyethylene menisci is a significant clinical problem.
At this regard, wear tests on biomaterials medical devices are performed in order to assess …

In vitro quantification of wear in tibial inserts using microcomputed tomography

MG Teeter, DDR Naudie, DD McErlain… - … and Related Research®, 2011 - Springer
Background Wear of polyethylene tibial inserts can decrease the longevity of total knee
arthroplasty. Wear is currently assessed using laboratory methods that may not permit …

Determining material loss from the femoral stem trunnion in hip arthroplasty using a coordinate measuring machine

MC Bone, RP Sidaginamale, JK Lord… - Proceedings of the …, 2015 - journals.sagepub.com
In contrast to the articulating and taper surfaces of failed total hip replacements, volumetric
wear analysis of trunnions is not routinely performed. Metal wear particles from the trunnion …

Relationship of surface damage appearance and volumetric wear in retrieved TKR polyethylene liners

CB Knowlton, P Bhutani… - Journal of Biomedical …, 2017 - Wiley Online Library
Recently developed techniques have enabled volume loss measurements on surgically
retrieved total knee replacements (TKR). However, it is not well understood how volume loss …

CMM–based procedure for polyethylene non-congruous unicompartmental knee prosthesis wear assessment

M Spinelli, S Carmignato, S Affatato, M Viceconti - Wear, 2009 - Elsevier
One of the most recent advances in knee replacement surgery is the Unicompartmental
Knee Prosthesis that involves the substitution of only one compartment. Uncertainties on the …