Postoperative complications in the primary tube versus trabeculectomy study during 5 years of follow-up
SJ Gedde, WJ Feuer, KS Lim, K Barton, S Goyal… - Ophthalmology, 2022 - Elsevier
Purpose To describe postoperative complications encountered in the Primary Tube Versus
Trabeculectomy (PTVT) Study during 5 years of follow-up. Design Multicenter randomized …
Trabeculectomy (PTVT) Study during 5 years of follow-up. Design Multicenter randomized …
Ahmed Glaucoma Valve Implantation to Reduce Intraocular Pressure: Updated Perspectives
G Arikan, U Gunenc - Clinical Ophthalmology, 2023 - Taylor & Francis
Trabeculectomy and glaucoma drainage device implantation are the most commonly
performed glaucoma surgeries worldwide. Although trabeculectomy is the gold standard, at …
performed glaucoma surgeries worldwide. Although trabeculectomy is the gold standard, at …
Management of endothelial disease without keratoplasty
FE Hakim, PC He, PB Veldman - Current opinion in …, 2022 - journals.lww.com
Management of endothelial disease without keratoplasty : Current Opinion in
Ophthalmology Management of endothelial disease without keratoplasty : Current Opinion …
Ophthalmology Management of endothelial disease without keratoplasty : Current Opinion …
A computational fluid dynamics investigation of endothelial cell damage from glaucoma drainage devices
Glaucoma drainage devices (GDDs) are prosthetic-treatment devices for treating primary
open-angle glaucoma. Despite their effectiveness in reducing intraocular pressures (IOP) …
open-angle glaucoma. Despite their effectiveness in reducing intraocular pressures (IOP) …
Long-term outcomes of Baerveldt glaucoma implant surgery in Japanese patients
K Iwasaki, R Komori, S Arimura, Y Orii, Y Takamura… - Scientific Reports, 2023 - nature.com
This study evaluated the long-term surgical outcomes of Baerveldt glaucoma implant (BGI)
surgery in patients with refractory glaucoma (204 eyes/204 patients). Surgical failure was …
surgery in patients with refractory glaucoma (204 eyes/204 patients). Surgical failure was …
Corneal endothelial cell loss after PRESERFLO™ MicroShunt implantation in the anterior chamber: anterior segment OCT tube location as a risk factor
M Ibarz-Barberá, L Morales-Fernández… - Ophthalmology and …, 2022 - Springer
Introduction To analyze the effects of PRESERFLO on corneal endothelial cell density
(ECD). Methods Forty-six eyes that underwent PRESERFLO implantation were followed up …
(ECD). Methods Forty-six eyes that underwent PRESERFLO implantation were followed up …
Corneal endothelial cell changes and surgical results after Ahmed glaucoma valve implantation: ciliary sulcus versus anterior chamber tube placement
JY Kim, JS Lee, T Lee, D Seo, W Choi, HW Bae… - Scientific reports, 2021 - nature.com
We compared the changes in corneal endothelial cells and surgical outcomes after Ahmed
glaucoma valve (AGV) implantation with the valve tip inserted either into ciliary sulcus (CS) …
glaucoma valve (AGV) implantation with the valve tip inserted either into ciliary sulcus (CS) …
Preserflo MicroShunt: efficacy and endothelial cell density
FA Steindor, C Trigaux, C Holtmann… - Journal of …, 2023 - journals.lww.com
Purpose: The purpose of this study was to evaluate the efficacy and corneal safety,
especially corneal endothelial cell loss (ECL), after Preserflo MicroShunt implantation …
especially corneal endothelial cell loss (ECL), after Preserflo MicroShunt implantation …
Different patterns in the corneal endothelial cell loss after pars plana and pars limbal insertion of the Baerveldt glaucoma implant
PURPOSE To assess corneal endothelial cell (CE) loss after pars plana (PP) and pars
limbal (PL) insertion of a Baerveldt glaucoma implant (BGI). DESIGN Retrospective …
limbal (PL) insertion of a Baerveldt glaucoma implant (BGI). DESIGN Retrospective …
Outcomes of anterior chamber, sulcus, and pars plana glaucoma drainage device placement in glaucoma patients
S Samuel, EK Chang, S Gupta… - Journal of …, 2022 - Wiley Online Library
Purpose. To assess outcomes of anterior chamber (AC), sulcus, and pars plana (PP)
glaucoma drainage device (GDD) placement in glaucoma patients. Patients and Methods …
glaucoma drainage device (GDD) placement in glaucoma patients. Patients and Methods …