[HTML][HTML] A critical review on control mechanisms, supporting measures, and monitoring systems of microgrids considering large scale integration of renewable energy …
M Hasan, Z Mifta, NA Salsabil, SJ Papiya, M Hossain… - Energy Reports, 2023 - Elsevier
The numerous obstacles to large-scale integration of renewable energy sources (RESs) and
the mitigating steps that need to be taken to overcome them in smart grid technology …
the mitigating steps that need to be taken to overcome them in smart grid technology …
An Overview and Minimum fault ramp rate analysis of Impedance based Circuit Breaker Topologies
JM Abdullah, V Sumathi - IEEE Access, 2023 - ieeexplore.ieee.org
In the advent of recent developments in a higher efficiency Direct Current (DC) system, the
DC microgrid proves to be a permissible future to match the load demand with distributed …
DC microgrid proves to be a permissible future to match the load demand with distributed …
Reducing Microgrids Integration Complexity in Distribution Networks Considering Bidirectional Power Flow in SFCLs
M Elsamahy - IEEE Access, 2022 - ieeexplore.ieee.org
In this paper, investigations are carried out to explore the application of the well-known
unique bidirectional power flow nature of superconducting fault current limiters (SFCLs) to …
unique bidirectional power flow nature of superconducting fault current limiters (SFCLs) to …
[PDF][PDF] Energy Reports
M Hasan, Z Mifta, NA Salsabil, SJ Papiya - 2023 - researchgate.net
abstract The estimation of wind potential is generally assessed using the two parameters of
Weibull distribution (k, c). Relative Percentage Error (RPE), Root Mean Square Error …
Weibull distribution (k, c). Relative Percentage Error (RPE), Root Mean Square Error …
Pemanfaatan SFCL tipe Bridge untuk Meningkatkan Stabilitas Transien Microgrid dan Economic Feasibility
Currently, renewable energy (RE) generators are widely used by society to reduce
emissions. Therefore, a RE-sourced microgrid system coexisting with conventional energy is …
emissions. Therefore, a RE-sourced microgrid system coexisting with conventional energy is …
Autonomous operation of microgrid and minimization of fault in case of failure in high-voltage lines
The manual reaction approach to faults is exhibited in conventional grid. Manual operations
are slow in many cases and resulting in big fault and power cut. Turkey has experienced it …
are slow in many cases and resulting in big fault and power cut. Turkey has experienced it …
[PDF][PDF] Autonomous operation of microgrid and minimization of fault in case of failure in high-voltage lines
MB SAYAN, C YILMAZ, M BULUT - academia.edu
Autonomous operation of microgrid and minimization of fault in case of failure in high-
voltage lines Yüksek gerilim hatlarınd Page 1 POLİTEKNİK DERGİSİ JOURNAL of …
voltage lines Yüksek gerilim hatlarınd Page 1 POLİTEKNİK DERGİSİ JOURNAL of …