Introduction to polymer-based solid-contact ion-selective electrodes—basic concepts, practical considerations, and current research topics
C Bieg, K Fuchsberger, M Stelzle - Analytical and Bioanalytical Chemistry, 2017 - Springer
This review aims at providing an introductory overview for researchers new to the field of ion-
selective electrodes. Both state of the art technology and novel developments towards solid …
selective electrodes. Both state of the art technology and novel developments towards solid …
Sensing of inorganic ions in microfluidic devices
R Wang, X Wang - Sensors and Actuators B: Chemical, 2021 - Elsevier
The past two decades witnessed the widespread adoption of microfluidics for miniaturized
and automated chemical analysis. Microfluidic techniques require less sample, consume …
and automated chemical analysis. Microfluidic techniques require less sample, consume …
PVC-based ion-selective electrodes with a silicone rubber outer coating with improved analytical performance
An outer layer of pure silicone rubber (SR), ie SR without any plasticizer, ionophore, or
lipophilic anion, was applied on top of a conventional poly (vinyl chloride)(PVC) based K+ …
lipophilic anion, was applied on top of a conventional poly (vinyl chloride)(PVC) based K+ …
Plasticizer‐free polymer membrane ion‐selective electrodes containing a methacrylic copolymer matrix
Y Qin, S Peper, E Bakker - Electroanalysis: An International …, 2002 - Wiley Online Library
A methyl methacrylate and decyl methacrylate (MMA‐DMA) copolymer has been used to
fabricate plasticizer‐free ion‐selective membranes. The copolymer matrix showed good …
fabricate plasticizer‐free ion‐selective membranes. The copolymer matrix showed good …
Polyaniline nanoparticle-based solid-contact silicone rubber ion-selective electrodes for ultratrace measurements
T Lindfors, J Szucs, F Sundfors… - Analytical …, 2010 - ACS Publications
Silicone rubber (SR)-based solid-contact ion-selective electrodes (ISEs) have been
prepared for the first time with an electrically conducting polymer as the solid-contact (SC) …
prepared for the first time with an electrically conducting polymer as the solid-contact (SC) …
Ion-selective potentiometric sensors with silicone sensing membranes: A review
XV Chen, P Bühlmann - Current Opinion in Electrochemistry, 2022 - Elsevier
Ion-selective electrodes (ISEs) are used widely in mainframe analyzers for clinical chemistry,
but there is also an increasing interest in the development of paper-based devices …
but there is also an increasing interest in the development of paper-based devices …
Influence of the Composition of Plasticizer-Free Silicone-Based Ion-Selective Membranes on Signal Stability in Aqueous and Blood Plasma Samples
Solid-contact ion-selective electrodes (SC-ISEs) in direct long-term contact with
physiological samples must be biocompatible and resistant to biofouling, but most wearable …
physiological samples must be biocompatible and resistant to biofouling, but most wearable …
FTIR-ATR study of water uptake and diffusion through ion-selective membranes based on poly (acrylates) and silicone rubber
F Sundfors, T Lindfors, L Hofler, R Bereczki… - Analytical …, 2009 - ACS Publications
For the first time, FTIR-ATR spectroscopy was used to study the water uptake and its
diffusion in ion-selective membranes (ISMs) based on poly (acrylates)(PAs) and silicone …
diffusion in ion-selective membranes (ISMs) based on poly (acrylates)(PAs) and silicone …
Solvent-processible polymer membrane-based liquid junction-free reference electrode
HJ Lee, US Hong, DK Lee, JH Shin, H Nam… - Analytical …, 1998 - ACS Publications
A new type of liquid junction-free reference electrode system is devised by employing
solvent-processible polymer membranes. The membranes are formulated with either a one …
solvent-processible polymer membranes. The membranes are formulated with either a one …
The Water Uptake of Plasticized Poly (vinyl chloride) Solid‐Contact Calcium‐Selective Electrodes
T Lindfors, F Sundfors, L Höfler… - Electroanalysis, 2011 - Wiley Online Library
A hyphenated method based on FTIR‐ATR and electrochemical impedance spectroscopy
has been applied to simultaneously measure the water uptake, changes in the bulk …