An analytical approach to model indirect effect caused by electrostatic discharge

O Fujiwara - IEICE transactions on communications, 1996 - search.ieice.org
It is well recognized that the electromagnetic interference due to indirect electrostatic
discharge (ESD) is not always proportional to the ESD voltage and also that the lower …

ESD: waveform calculation, field and current of human and simulator ESD

D Pommerenke, M Aidam - Journal of ELECTROSTATICS, 1996 - Elsevier
Currents, current derivatives and transient fields of human ESDs are compared to currents
and fields caused by commercial simulators. The results point at undefined but influential …

Broadband measurement of ESD risetimes to distinguish between different discharge mechanisms

S Bönisch, D Pommerenke, W Kalkner - Journal of Electrostatics, 2002 - Elsevier
Different discharge mechanisms are possible for electrostatic discharge below 2000 V
breakdown voltage as a function of the parameters gap distance, breakdown voltage …

To what extent do contact-mode and indirect ESD test methods reproduce reality?

D Pommerenke, M Aidam - Electrical Overstress/Electrostatic …, 1995 - ieeexplore.ieee.org
Currents, current derivatives and transient fields of ESDs of humans are compared to
currents and fields caused by simulators. A method for the simulation of the discharge …

Fields on the horizontal coupling plane excited by direct ESD and discharges to the vertical coupling plane

S Frei, D Pommerenke - Journal of Electrostatics, 1998 - Elsevier
Field levels in indirect electrostatic discharge (ESD) test setups are hardly known yet. It has
been proposed to ANSI and IEC to use a horizontal simulator position instead of a vertical …

An analysis of the fields on the horizontal coupling plane in ESD testing

S Frei, D Pommerenke - Proceedings Electrical Overstress …, 1997 - ieeexplore.ieee.org
Field levels in indirect Electrostatic Discharge (ESD) test setups are not known yet. has been
proposed to ANSI and IEC to use a horizontal simulator position instead of a vertical position …

Level estimation of transient electromagnetic fields caused by spark discharge between charged metal spheres

O Fujiwara, T Hori - IEEJ Transactions on Electronics, Information …, 1997 - jstage.jst.go.jp
Level Estimation of Transient Electromagnetic Fields Caused by Spark Discharge between
Charged Metal Spheres Osamu Fujiwara, Member, Takeo Hori, Non-member (Nagoya …

Level Estimation of Magnetic Far-Field Generated by Spark Discharge Between Charged Metal Spheres

O Fujiwara, M Funato, H Seko - IEEJ Transactions on Electronics …, 2001 - jstage.jst.go.jp
Osamu Fujiwara, Member, Motonobu Funato, Non-member, Hideaki Seko, Non-member
(Faculty of Engineering, Nagoya Institute of Technology) The ESD (electrostatic discharge) …

Numerical calculation of ESD

Jobava, Karkashadze, Zaridze… - 1996 Proceedings …, 1996 - ieeexplore.ieee.org
A non linear time domain method of moments algorithm is presented. It allows the
calculation of transient fields of ESD from bodies of revolution. The arc is taken into account …

[PDF][PDF] Die elektrostatische Entladung (ESD) bei kleinen Abständen und Spannungen

SP Bönisch - 2004 - depositonce.tu-berlin.de
Die vorliegende Arbeit berichtet über elektrostatische Entladungen (ESD) mit
Durchbruchspannungen< 2000 V bzw. Elektrodenabständen< 300 µm. Zur …