Task-driven source–detector trajectories in cone-beam computed tomography: I. Theory and methods

JW Stayman, S Capostagno, GJ Gang… - Journal of Medical …, 2019 - spiedigitallibrary.org
We develop a mathematical framework for the design of orbital trajectories that are optimal
to a particular imaging task (or tasks) in advanced cone-beam computed tomography …

A scanner-specific framework for simulating CT images with tube current modulation

G Jadick, E Abadi, B Harrawood… - Physics in Medicine …, 2021 - iopscience.iop.org
Although tube current modulation (TCM) is routinely implemented in modern computed
tomography (CT) scans, no existing CT simulator is capable of generating realistic images …

Dual source hybrid spectral micro-CT using an energy-integrating and a photon-counting detector

MD Holbrook, DP Clark, CT Badea - Physics in Medicine & …, 2020 - iopscience.iop.org
Preclinical micro-CT provides a hotbed in which to develop new imaging technologies,
including spectral CT using photon counting detector (PCD) technology. Spectral imaging …

Task-driven source–detector trajectories in cone-beam computed tomography: II. Application to neuroradiology

S Capostagno, JW Stayman… - Journal of Medical …, 2019 - spiedigitallibrary.org
We apply the methodology detailed in “Task-driven source–detector trajectories in cone-
beam computed tomography: I. Theory and methods” by Stayman et al. for task-driven …

Image quality and dose characteristics for an O‐arm intraoperative imaging system with model‐based image reconstruction

A Uneri, X Zhang, T Yi, JW Stayman, PA Helm… - Medical …, 2018 - Wiley Online Library
Purpose To assess the imaging performance and radiation dose characteristics of the O‐
arm CBCT imaging system (Medtronic Inc., Littleton MA) and demonstrate the potential for …

Task-driven optimization of fluence field and regularization for model-based iterative reconstruction in computed tomography

GJ Gang, JH Siewerdsen… - IEEE transactions on …, 2017 - ieeexplore.ieee.org
This paper presents a joint optimization of dynamic fluence field modulation (FFM) and
regularization in quadratic penalized-likelihood reconstruction that maximizes a task-based …

Statistical weights for model-based reconstruction in cone-beam CT with electronic noise and dual-gain detector readout

P Wu, JW Stayman, A Sisniega… - Physics in Medicine …, 2018 - iopscience.iop.org
Cone-beam CT (CBCT) systems commonly incorporate a flat-panel detector (FPD) with
multiple-gain readout capability to reduce electronic noise and extend dynamic range. In this …

Effects of image quality on the fundamental limits of image registration accuracy

MD Ketcha, T De Silva, R Han, A Uneri… - IEEE transactions on …, 2017 - ieeexplore.ieee.org
For image-guided procedures, the imaging task is often tied to the registration of
intraoperative and preoperative images to a common coordinate system. While the accuracy …

Trajectory optimization for sparsely sampled computed tomography

F Bauer - 2022 - mediatum.ub.tum.de
Industrial computed tomography systems usually implement circular or helical trajectories,
which are inherently inefficient since they are applied independently of the inspection task …

Low‐dose cone‐beam CT via raw counts domain low‐signal correction schemes: Performance assessment and task‐based parameter optimization (Part II. Task …

D Gomez‐Cardona, JW Hayes, R Zhang, K Li… - Medical …, 2018 - Wiley Online Library
Purpose Different low‐signal correction (LSC) methods have been shown to efficiently
reduce noise streaks and noise level in CT to provide acceptable images at low‐radiation …