Passive harmonic filter design considering voltage sag performance-applicable to large industries

S Shakeri, S Esmaeili… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Nowadays, nonlinear loads such as load commutated inverter (LCI) drives are being used
by industrial sector throughout the world. However, despite the LCI drive uses low-cost …

Multi‐criteria decision‐making approach for optimal and probabilistic planning of passive harmonic filters in harmonically polluted industrial network with photovoltaic …

J Khajouei, S Shakeri, S Esmaeili… - IET Renewable …, 2023 - Wiley Online Library
Nowadays, nonlinear loads are widely employed within the industrial applications that
cause harmonic distortions in the network. Passive harmonic filters stand out as the …

Optimal power quality monitor placement to ensure reliable monitoring of sensitive loads in the presence of voltage sags and harmonic resonances conditions

S Shakeri, MHR Koochi, H Ansari, S Esmaeili - Electric Power Systems …, 2022 - Elsevier
Nowadays, sensitive nonlinear loads such as load commutated inverter drives are
increasingly being used by industrial consumers. In one hand, sensitive nonlinear loads can …

Improving the area of harmonic pollution and vulnerability to voltage sag for compatible and reliable operation of sensitive harmonic loads

S Shakeri, J Khajouei, S Esmaeili… - IET Generation …, 2022 - Wiley Online Library
Nowadays, sensitive harmonic loads (SHLs) are being increasingly used in the industrial
sector. SHLs generate harmonics and may become disconnected from the network when …

Passive Power Filter Optimization Problem Based on Adaptive Multipopulation NSGA‐II and CRITIC‐TOPSIS

Y Yuan, C Liu - Mathematical Problems in Engineering, 2022 - Wiley Online Library
The best configuration of passive filters in extra‐high voltage systems is investigated in this
study using a two‐stage multiobjective decision‐making (MODM) framework. A collection of …

Control of hybrid active power filter to reduce harmonics of 3-phase Cap-less inverter

DG Lee, RY Kim - Journal of Electrical Engineering & Technology, 2023 - Springer
Recently, material cost competitiveness in various fields, by applying a cap-less inverter
technology that uses a small capacity film capacitor to the dc link, the harmonics of input …

Determination of Optimal Locations and Parameters of Passive Harmonic Filters in Unbalanced Systems Using the Multiobjective Genetic Algorithm

MJ Milovanovic, SS Raicevic, DO Klimenta… - Elektronika ir …, 2024 - eejournal.ktu.lt
This paper discusses the problem of optimal placement and sizing of passive harmonic
filters to mitigate harmonics in unbalanced distribution systems. The problem is formulated …

Technical and Economic Analysis of Voltage Sags Mitigation Methods

S Shakeri, J Khajouei, S Esmaeili - 2022 30th International …, 2022 - ieeexplore.ieee.org
Nowadays, sensitive equipment to voltage sags such as adjustable speed drives (ASD) and
load commutated inverter (LCI) drives are being used by many industrial customers …

Design and Simulation of Hybrid Shunt Active Filter for PQ Improvement using PID Genetic Algorithm Controller in 3ϕ-4 Wire System

KR Sugavanam, P Selvaraju… - … Series: Earth and …, 2023 - iopscience.iop.org
This paper provides an economical solution and advanced method by tuning and optimizing
system for power in the transmission line. The proposed system uses PID Genetic Algorithm …

[PDF][PDF] Performance improvement of the shunt active power filter using a novel adaptive filtering approach.

A Zoghbi, D Berkani - Turkish J. Electr. Eng. Comput. Sci., 2021 - academia.edu
This paper introduces an efficient control approach to enhance harmonics mitigation
performance of the shunt active power filter (SAPF). This approach is based on adaptive …