A low-power on-chip ECG monitoring system based on MWCNT/PDMS dry electrodes

NT Tasneem, SA Pullano, CD Critello… - IEEE Sensors …, 2020 - ieeexplore.ieee.org
Wearable technologies have established novel strategies for continuous electrocardiogram
(ECG) monitoring, exploiting recent developments in sensors and integrated circuit …

Origins of ECG and evolution of automated DSP techniques: a review

N Arora, B Mishra - IEEE Access, 2021 - ieeexplore.ieee.org
Over the years, researchers have studied the evolution of Electrocardiogram (ECG) and the
complex classification of cardiovascular diseases. This review focuses on the evolution of …

Silicones for encapsulation of medical device implants

Y Poojari - Silicon, 2017 - Springer
Encapsulation of medical device implants with a suitable material is an essential and critical
process step in the manufacturing of a wide range of medical device products and for their …

A baseline wander tracking system for artifact rejection in long-term electrocardiography

T Niederhauser, L Kohler, A Haeberlin… - IEEE transactions on …, 2015 - ieeexplore.ieee.org
Long-term electrocardiogram (ECG) signals might suffer from relevant baseline disturbances
during physical activity. Motion artifacts in particular are more pronounced with dry surface …

Influence of implantation on the electrochemical properties of smooth and porous TiN coatings for stimulation electrodes

S Meijs, C Sørensen, S Sørensen… - Journal of neural …, 2016 - iopscience.iop.org
Objective. To determine whether changes in electrochemical properties of porous titanium
nitride (TiN) electrodes as a function of time after implantation are different from those of …

Graphics-processor-unit-based parallelization of optimized baseline wander filtering algorithms for long-term electrocardiography

T Niederhauser, T Wyss-Balmer… - IEEE Transactions …, 2015 - ieeexplore.ieee.org
Long-term electrocardiogram (ECG) often suffers from relevant noise. Baseline wander in
particular is pronounced in ECG recordings using dry or esophageal electrodes, which are …

Influence of fibrous encapsulation on electro-chemical properties of TiN electrodes

S Meijs, M Fjorback, C Jensen, S Sørensen… - Medical Engineering & …, 2016 - Elsevier
Highlights•Influence of encapsulation on electrochemical properties of TiN neural
electrodes.•Healing and encapsulation occurred during the first 3–4 weeks.•Electrode …

The genre of applications requiring long-term and continuous monitoring of ECG signals

M Bansal, B Gandhi - 2017 International Conference on …, 2017 - ieeexplore.ieee.org
Presently, cardiovascular issues have become an emerging challenge for physiologists and
researchers. Due to the fact, that the population is growing at a rapid pace and of course …

Feasibility of transesophageal phrenic nerve stimulation

EM Kaufmann, S Krause, L Geisshuesler… - Biomedical engineering …, 2023 - Springer
Background Every year, more than 2.5 million critically ill patients in the ICU are dependent
on mechanical ventilation. The positive pressure in the lungs generated by the ventilator …

[HTML][HTML] Respiratory rate estimation from multi-channel signals using auto-regulated adaptive extended Kalman filter

N Gupta, P Simmen, D Trachsel, A Haeberlin… - … Signal Processing and …, 2023 - Elsevier
Background: Respiration rate (RR) is a major cause for false alarms in intensive care units
(ICU) and is primarily impaired by the artifact prone signals from skin-attached electrodes …