Electrochemical sensing of hydrogen peroxide using metal nanoparticles: a review

S Chen, R Yuan, Y Chai, F Hu - Microchimica Acta, 2013 - Springer
We are reviewing the state of electrochemical sensing of H 2 O 2 based on the use of metal
nanoparticles. The article is divided into subsections on sensors based on nanoparticles …

Advances in enzyme-free electrochemical sensors for hydrogen peroxide, glucose, and uric acid

X Chen, G Wu, Z Cai, M Oyama, X Chen - Microchimica Acta, 2014 - Springer
Enzyme-free (also called non-enzymatic or direct) electrochemical sensors have been
widely used for the determination of hydrogen peroxide, glucose, and uric acid. This review …

Rh single-atom nanozymes for efficient ascorbic acid oxidation and detection

X Shi, J Li, Y Xiong, Z Liu, J Zhan, B Cai - Nanoscale, 2023 - pubs.rsc.org
The management of ascorbic acid (AA) in biological fluids is of significant importance for
body functions and human health, yet challenging due to the lack of high-performance …

Biosensors incorporating bimetallic nanoparticles

J Rick, MC Tsai, BJ Hwang - Nanomaterials, 2015 - mdpi.com
This article presents a review of electrochemical bio-sensing for target analytes based on
the use of electrocatalytic bimetallic nanoparticles (NPs), which can improve both the …

High sensitive and selective sensing of hydrogen peroxide released from pheochromocytoma cells based on Pt-Au bimetallic nanoparticles electrodeposited on …

G Yu, W Wu, X Pan, Q Zhao, X Wei, Q Lu - Sensors, 2015 - mdpi.com
In this study, a high sensitive and selective hydrogen peroxide (H2O2) sensor was
successfully constructed with Pt-Au bimetallic nanoparticles (Pt-Au NPs)/reduced graphene …

Electrochemical detection of arsenic in various water samples

M Rajkumar, S Thiagarajan, SM Chen - International Journal of …, 2011 - Elsevier
Nano Au-crystal violet (CRV) film has been fabricated on glassy carbon electrode (GCE) and
indium tin oxide glass electrode (ITO) using cyclic voltammetry. The nano Au-CRV film …

Enhanced electrocatalytic oxidation of isoniazid at electrochemically modified rhodium electrode for biological and pharmaceutical analysis

S Cheemalapati, SM Chen, MA Ali… - Colloids and Surfaces B …, 2014 - Elsevier
A simple and sensitive electrochemical method has been proposed for the determination of
isoniazid (INZ). For the first time, rhodium (Rh) modified glassy carbon electrode (GCE) has …

Bimetallic PdCu/SPCE non-enzymatic hydrogen peroxide sensors

A Uzunoglu, AD Scherbarth, LA Stanciu - Sensors and Actuators B …, 2015 - Elsevier
Screen printed carbon electrodes (SPCE) were decorated with PdCu bimetallic alloys via a
facile co-electrodeposition method to develop disposable non-enzymatic H 2 O 2 sensors …

Metal nanoparticles for electrochemical sensing applications

S Aralekallu, LK Sannegowda - Handbook of Nanomaterials for Sensing …, 2021 - Elsevier
This chapter describes the recent advances in metal nanoparticles (MNPs) for
electrochemical-sensing applications. MNPs have attracted researchers' attention because …

A sensitive electrochemical H2O2 sensor based on PdAg-decorated reduced graphene oxide nanocomposites

A Uzunoglu, S Song, LA Stanciu - Journal of the Electrochemical …, 2016 - iopscience.iop.org
We report on the construction of PdAg/reduced graphene oxide (rGO)-based
electrochemical H 2 O 2 sensors by exploiting the high surface area and fast electron …