[图书][B] Guidelines for using activated sludge models

L Rieger, S Gillot, G Langergraber, T Ohtsuki, A Shaw… - 2012 - books.google.com
Mathematical modelling of activated sludge systems is used widely for plant design,
optimisation, training, controller design and research. The quality of simulation studies …

[PDF][PDF] Towards quantitative quality criteria to evaluate simulation results in wastewater treatment–A critical review

H Hauduc, MB Neumann, D Muschalla… - … 8th symposium on …, 2011 - academia.edu
A total of 31 quantitative quality criteria to compare measured with simulated time series in
environmental modelling are critically reviewed. They are grouped using two classification …

A validation workflow for treatment wetland performance data

SHY Guillaume-Ruty, J Pueyo-Ros… - Water Science & …, 2024 - iwaponline.com
Treatment wetlands (TWs) effectively remove target pollutants and enhance urban water
circularity and resilience. They constitute a prominent solution for urban wastewater …

Modelling the nitrification in a full-scale tertiary biological aerated filter unit

J Bernier, V Rocher, S Guerin, P Lessard - Bioprocess and Biosystems …, 2014 - Springer
A wastewater biofiltration model is used to assess its capacity to reproduce the treatment
behaviour of a plant-sized tertiary nitrifying biofilter unit. It is calibrated on two different types …

A Practical Methodology for Forecasting the Impact of Changes in Influent Loads and Discharge Consents on Average Energy Consumption and Sludge Production by …

C Silva, MJ Rosa - Sustainability, 2021 - mdpi.com
This paper proposes a simple and easy-to-use methodology for forecasting the impact of
changes in influent chemical oxygen demand (COD) and in the emission limit values (ELVs) …

Initial and hourly headloss modelling on a tertiary nitrifying wastewater biofiltration plant

J Bernier, V Rocher, P Lessard - Environmental Technology, 2016 - Taylor & Francis
The headloss prediction capability of a wastewater biofiltration model is evaluated on data
from a full-scale tertiary nitrifying biofilter unit located in the Paris conurbation (Achères …

Modelling headloss and two-step denitrification in a full-scale wastewater post-denitrifying biofiltration plant

J Bernier, V Rocher, P Lessard - Journal of Environmental …, 2014 - icevirtuallibrary.com
The NO3−/NO2− removal and headloss evolution behaviour of a post-denitrification
wastewater biofiltration stage using methanol as an external carbon source was modelled …

Diagnostic de défauts par les Machines à Vecteurs Supports: application à différents systèmes mutivariables nonlinéaires

N Laouti - 2012 - theses.hal.science
Les systèmes réels sont généralement de nature non-linéaire, et leurs modélisations
etsurveillance restent une tâche difficile à accomplir. Néanmoins, avec les progrès …

Réduction des polluants organiques des eaux usées de la région de Touggourt par des plantes épuratrices locales (Système à écoulement hybride)

A ZORAI - 2023 - dspace.univ-ouargla.dz
Les systèmes de zones humides artificielles constituent une alternative économique au
traitement des eaux usées dans les pays en développement. Par conséquent, afin …

[PDF][PDF] Analyse et consolidation de données de fonctionnement des stations d'épuration: une étude de cas

A Filali, H Hauduc, L Rieger, L Philippe… - … , génie urbain génie …, 2015 - researchgate.net
Les stations de traitement des eaux résiduaires en France fonctionnent majoritairement
selon le principe des boues activées [GOLLA et al., 2010]. Dans ce procédé conventionnel …