Mechanics and microstructure of the atrioventricular heart valve chordae tendineae: A review

CJ Ross, J Zheng, L Ma, Y Wu, CH Lee - Bioengineering, 2020 - mdpi.com
The atrioventricular heart valves (AHVs) are responsible for directing unidirectional blood
flow through the heart by properly opening and closing the valve leaflets, which are …

Parameterization, geometric modeling, and isogeometric analysis of tricuspid valves

EL Johnson, DW Laurence, F Xu, CE Crisp… - Computer methods in …, 2021 - Elsevier
Approximately 1.6 million patients in the United States are affected by tricuspid valve
regurgitation, which occurs when the tricuspid valve does not close properly to prevent …

FEBio FINESSE: An open-source finite element simulation approach to estimate in vivo heart valve strains using shape enforcement

DW Laurence, PM Sabin, AM Sulentic… - Annals of Biomedical …, 2024 - Springer
Purpose Finite element simulations are an enticing tool to evaluate heart valve function;
however, patient-specific simulations derived from 3D echocardiography are hampered by …

A pilot in silico modeling‐based study of the pathological effects on the biomechanical function of tricuspid valves

DW Laurence, EL Johnson, MC Hsu… - … journal for numerical …, 2020 - Wiley Online Library
Current clinical assessment of functional tricuspid valve regurgitation relies on metrics
quantified from medical imaging modalities. Although these clinical methodologies are …

A pilot study on linking tissue mechanics with load-dependent collagen microstructures in porcine tricuspid valve leaflets

LT Hudson, SV Jett, KE Kramer, DW Laurence… - Bioengineering, 2020 - mdpi.com
The tricuspid valve (TV) is composed of three leaflets that coapt during systole to prevent
deoxygenated blood from re-entering the right atrium. The connection between the TV …

[HTML][HTML] Mechanical and morphometric study of mitral valve chordae tendineae and related papillary muscle

S Chen, CR Sari, H Gao, Y Lei, P Segers… - journal of the …, 2020 - Elsevier
The mitral valve (MV) apparatus is a complex mechanical structure including annulus, valve
leaflets, papillary muscles (PMs) and connected chordae tendineae. Chordae anchor to the …

Quantification of load-dependent changes in the collagen fiber architecture for the strut chordae tendineae-leaflet insertion of porcine atrioventricular heart valves

CJ Ross, MC Hsu, R Baumwart, A Mir… - … and modeling in …, 2021 - Springer
Atrioventricular heart valves (AHVs) regulate the unidirectional flow of blood through the
heart by opening and closing of the leaflets, which are supported in their functions by the …

Effect of Parametric Variation of Chordae Tendineae Structure on Simulated Atrioventricular Valve Closure

NR Mangine, DW Laurence, PM Sabin, W Wu… - arXiv preprint arXiv …, 2024 - arxiv.org
Many approaches have been used to model chordae tendineae geometries in finite element
simulations of atrioventricular heart valves. Unfortunately, current" functional" chordae …

Effect of the Location of Strut Chordae Insertion on Computational Modeling and Biomechanical Evaluation of Mitral Valve Dynamics

W Hong, S Jeong, M Ko, HH Kim, H Kim - Applied Sciences, 2021 - mdpi.com
The strut chordae (SC) have a unique structure and play an important role in reinforcing the
tunnel-shaped configuration of the mitral valve (MV) at the inflow and outflow tracts. We …

Viscoelastic modelling of the tricuspid valve chordae tendineae tissue

LW Liu, CH Lee, A Aggarwal, CM Chao… - Applied Mathematical …, 2022 - Elsevier
In the present study, the mechanical behavior of tricuspid valve (TV) chordae tendineae
tissue is investigated experimentally and theoretically. A series of uniaxial mechanical …