The slow Arrhenius process in small organic molecules
F Caporaletti, S Napolitano - Physical Chemistry Chemical Physics, 2024 - pubs.rsc.org
Equilibration, the complex set of molecular rearrangements leading to more stable states, is
usually dominated by density fluctuations, occurring through the structural (α-) relaxation …
usually dominated by density fluctuations, occurring through the structural (α-) relaxation …
Twofold facet of kinetics of glass aging
V Di Lisio, LA Rocchi, D Cangialosi - Physical Review Letters, 2024 - APS
We employ fast scanning calorimetry to monitor the isothermal aging kinetics in glassy
polymers, complemented with measurements on other glasses. Apart from following the time …
polymers, complemented with measurements on other glasses. Apart from following the time …
Kinetics of physical aging of a silicate glass following temperature up-and down-jumps
In this article, we investigate the structural relaxation of lithium silicate glass during
isothermal physical aging by monitoring the temporal evolution of its refractive index and …
isothermal physical aging by monitoring the temporal evolution of its refractive index and …
Physical aging and vitrification in polymers and other glasses: Complex behavior and size effects
D Cangialosi - Journal of Polymer Science, 2024 - Wiley Online Library
The paradigmatic view on the transformation of a supercooled liquid into a glass, so‐called
vitrification or glass transition, and the subsequent time evolution of the non‐equilibrium …
vitrification or glass transition, and the subsequent time evolution of the non‐equilibrium …
Length scale of molecular motions governing glass equilibration in hyperquenched and slow-cooled polystyrene
J Luo, X Wang, B Tong, Z Li, LA Rocchi… - The Journal of …, 2024 - ACS Publications
Polymer glasses attain thermodynamic equilibrium owing to structural relaxation at various
length scales. Herein, calorimetry experiments were conducted to trace the macroscopic …
length scales. Herein, calorimetry experiments were conducted to trace the macroscopic …
Nonlinear susceptibilities and higher-order responses related to physical aging: Wiener–Volterra approach and extended Tool–Narayanaswamy–Moynihan models
K Moch, C Gainaru, R Böhmer - The Journal of Chemical Physics, 2024 - pubs.aip.org
Large-amplitude thermal excursions imposed on deeply supercooled liquids modulate the
nonlinear time evolution of their structural rearrangements. The consequent aftereffects are …
nonlinear time evolution of their structural rearrangements. The consequent aftereffects are …
Temperature oscillations provide access to high-order physical aging harmonics of a glass forming melt
K Moch, R Böhmer, C Gainaru - The Journal of Chemical Physics, 2023 - pubs.aip.org
A high-resolution, temperature oscillation-based probe of physical aging in complex systems
is introduced. The Fourier analysis of the measured responses allows one to extract high …
is introduced. The Fourier analysis of the measured responses allows one to extract high …
Effect of physical aging on ionic conductivity of network oxide glasses
This study investigates the effect of α-relaxation induced by physical aging due to a down-
jump in fictive temperature (T f) on the alkali ion hopping dynamics and the resulting ionic …
jump in fictive temperature (T f) on the alkali ion hopping dynamics and the resulting ionic …
Single parameter aging and density scaling
T Hecksher, K Niss - The Journal of Chemical Physics, 2024 - pubs.aip.org
In a recent paper, Di Lisio et al.[J. Chem. Phys. 159, 064505 (2023)] analyzed a series of
temperature down-jumps using the single-parameter aging (SPA) ansatz combined with a …
temperature down-jumps using the single-parameter aging (SPA) ansatz combined with a …
Crossing the Frontier of Validity of the Material Time Approach in the Aging of a Molecular Glass
M Hénot, XA Nguyen, F Ladieu - The Journal of Physical …, 2024 - ACS Publications
We studied the physical aging of glycerol in response to upward temperature steps of
amplitude ranging from 0.3 to 18 K. This was done using a specially designed experimental …
amplitude ranging from 0.3 to 18 K. This was done using a specially designed experimental …